Desa (V)VC42P, CGCDV42NR, CGCDV42PR installation manual Burner Pan Assembly

Page 41

PARTS LIST

Burner assembly for models VC42N, VVC42N, VC42P, VVC42P, cgcDV42nr and cgcDV42pr Series

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual.

KEY PART

 

NO. NUMBER DESCRIPTION

QTY.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

**

Burner Pan Assembly

**

Base Grate

**

Firebox Base Bottom

**

Valve Bracket

11107

Screw, #10-32 x 1/4 Zinc

**

Firebox Bottom

11102

Screw, #8-32 x 3/8 Zinc

116344-01

Tubing Assembly

111288-02

Flex Gas Line

108084-02

Pilot Assembly (Natural Gas)

108084-03

Pilot Assembly (Propane/LP Gas)

108084-05

Pilot Assembly (-HA Models)

14389

Natural Gas Valve

14390

Propane/LP Gas Valve

117370-01

Natural Gas High Altitude Valve

11165

Screw, #10 x 5/8 Zinc

111913-01

Burner Base Gasket

14396

Brass Fitting

116345-01

Pilot Bracket

26827

Switch Bracket

11226

Flat Washer 7/8" ID x 2" OD

11214

Bulkhead Fitting with Washer

14296

Elbow 3/8"

24874

Burner Orifice #32 (Natural Gas)

23098

Burner Orifice #50 (Propane/LP Gas)

14492

Piezo Ignitor

14511

Piezo Bracket

PARTS AVAILABLE - NOT SHOWN

1

1

1

1

4

1

2

1

1

1

1

1

1

1

1

23

1

2

1

1

2

2

1

1

1

1

1

108085-03 Pilot Injector #62 (-HA Models Only) **Not a field replaceable part.

1

116236-01G

www.desatech.com

41

Image 41
Contents Patent Pending What to do if YOU Smell GASSafety Information Table of ContentsSafety Information High traffic areas Product IdentificationLocal Codes Pre-Installation Preparation Product FeaturesLocation and space requirements This fireplace does not require electricity to operateMinimum clearances to combustibles for Clearances42 1067 mm Front 36 914 mm Top of Standoffs VentFireplace Framing and finishingNoncombustible mantels at any height above Balcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Corner InstallationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsInstalling optional blower accessories Fireplace InstallationModel BK Installation Plug in blower power cordBlower Model BKT Model BKT InstallationInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Propane/LP From Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Checking GAS ConnectionsInstalling Remote Receiver Pressure Testing Fireplace Gas ConnectionsRemoving/Replacing Glass Door Replace battery cover onto remote control unitRemoving Louver Panels Removing Glass DoorInstalling Brick liner Models BL42DASA and BL42DHASA Installing lava rock and glowing embersReplace screen/rod assembly by reversing step Cleaning Glass DoorOperating Fireplace For your safety Read before lightingLighting Instructions Close top and bottom louversRemote Operation To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Thermostat Series Model HRC200 On/Off Series Model HRC100Pilot assembly Operating optional blower accessoryKey Pad Lock Feature Inspecting BurnersGlass Door Cleaning MaintenanceBurner Flame Pattern Venting system Pilot and burnersLogs Observed Problem Possible Cause Remedy TroubleshootingBurner orifice clogged Clean burner see Cleaning Is lit Problem could be caused by Replace pilot assemblyAfter pilot lights, keep gas Long enough Control knob pressedTery power is low When burner is lit HI position when burner isTurning gas control knob to Cold Minute Air in gas line Operate burner until air isStatement above Gas leak. See WarningService Hints Replacement PartsTechnical Service SpecificationsIllustrated Parts Breakdown Parts List 19 18 116236-01G Burner Pan Assembly Accessories GwmS2 Not Shown Wall mounted on/off switchWall mounted thermostat control kit gwmt1 Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty