Fireplace
Installation
Continued
Pressure Testing Fireplace Gas
Connections
1. Open equipment shutoff valve (see Figure 34, page 23).
2. Open propane/LP supply tank valve or main gas valve located on or near gas meter for natural gas.
3. Make sure control knob of fireplace is in the OFF position.
4. Check all joints from equipment shutoff valve to gas valve (see Figure 35 or 36, page 23). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.
5. Light fireplace (see Operating Fireplace, page
27). Check all other internal joints for leaks.
6. Turn off fireplace (see To Turn Off Gas to Appliance, page 28).
Installing optional wall Mount Switch - gwmS2
Installing Optional Wireless
NOTICE: Use only alkaline bat- teries (not included).
Installing Remote Receiver
1. Open bottom louver and locate the switch bracket on the right.
2. Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver.
3. Locate the battery clip mounted on the back of the receiver. Slide a
4. Attach the terminal wires to the battery.
5. Connect wires from receiver to TH and TPTH to control valve (see Figure 39).
6. Replace the switch bracket.
Receiver
1. Connect one terminal of 25 ft. wire for the |
wall switch to the TPTH terminal on the |
valve. Connect remaining wire terminal to the |
TH terminal on the valve. Make sure that the |
wire terminals are in the positions on the unit |
9-Volt
Terminal Wires
| as pictured in Figure 37. If wires are not con- |
| nected as shown the switch will not work. |
2. | Route the 25 ft. wire through openings pro- |
| vided on the sides of the burner system to a |
| convenient location to mount your switch. |
3. | Connect one bare wire end to each of the |
| terminals of the GWMS2 wall switch. |
4. | Install the wall switch and cover in the wall. |
To Wall
Switch
Accessory
AlkalineBattery Clip Battery
Figure 38 - Attaching Alkaline Battery to
Receiver
To Optional
Remote
Accessory
Figure 39 - Control Valve Terminals
Figure 37 - Connecting Wall Switch to
Control Valve
24 | www.desatech.com |