Vermont Casting DVT38S2IN Remote Control Transmitter Operating Instructions, Introduction

Page 10

Chateau™ Direct Vent Gas Fireplace

Remote Control Transmitter

Operating Instructions

Introduction

This transmitter operating range is approximately 20 feet (6 m). The transmitter operates on one of 1,048,576 security codes that are programmed into the transmitter at the factory; this transmitter operates on radio frequencies with non-

Transmitter

On H/L

��

Button

 

Off

ON H/L

Continuous

OFF/CONTINUOUS

Pilot Button

PILOT BUTTON

 

Mode Button

MODE

 

 

SET

Set Button

 

Wall Clip

Slot

Battery

Compartment

The transmitter operates on (2) 1.5V AAA batteries. It is recom- mended that ALKALINE batteries always be used for longer battery life and maximum operational performance.

Before using the transmitter, install the (2) AAA transmitter bat- teries into the battery compartment. (Use caution that batteries are installed in the proper direction.)

FP1818

ON H/L

1

Key Settings

OFF

Continuous 2

Pilot

MODE

3

SET

4

1. ON H/L

— Turns unit to ON and operates

 

the flame control HI or LO.

2.OFF

CONTINUOUS PILOT — Shuts the unit OFF and acti-

 

 

vates the continuous pilot on

 

 

feature.

3.

MODE

— Changes unit from manual

 

 

mode to thermostatic mode.

4.

SET

— Sets temperature in thermo

 

 

mode.

LCD - Liquid Crystal Display

7

1

4

 

 

 

1.

DISPLAY

Indicates CURRENT room temperature.

�����

 

2

2.

° F or ° C Indicates degrees Fahrenheit or Celsius

 

3. FLAME

Indicates burner/valve in operation

 

 

 

 

 

4.

ROOM

Indicates remote is in THERMOSTATIC mode

 

 

3 5.

TEMP

Appears during manual operation

 

 

 

6.

SET

Appears while setting the desired tem-

 

 

 

 

 

perature in the thermostatic mode

����

��� ����

5

7.

PILOT

Appears in the Continuous Pilot mode

 

 

 

6

10

20011957

Image 10
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Ansi Z21.50b-2005 / CSA 2.22b-2005 Vented Gas Fireplace Installation & Operating InstructionsCertified To Please Review the Following CarefullyLocating Your Fireplace Standard FramingClearance to Combustibles MantelsFinal Finishing HearthFraming and Finishing Gas Specifications High Elevations Gas Line Installation Gas Inlet and Manifold Pressures Electrical Junction BoxControl System Installation Control SystemSpecial Feature for Cold Climates Chateau Direct Vent Gas FireplaceIntroduction Remote Control Transmitter Operating InstructionsKey Settings LCD Liquid Crystal DisplayManual Function Thermostat FunctionCP Childproof Feature Continuous Pilot FeatureSetting LOCK-OUT CP Thermostatic Updating Feature Operational NotesGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationUSA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Vertical Termination Horizontal TerminationSidewall Applications Sidewall Installation StepAlways install horizontal venting on a level plane Zero clearance sleeve is only required for combustible wallsSidewall Installation with Stationary Glass Facing Outside Horizontal length requirementInstallation Procedure Installing the 38S2VDK DoorFlue Restrictor Plate Guide Flue Restrictor Plate InstallationRestrictor Plate Installation Typical ApplicationsFlue restrictor plate use in straight up installation Vertical Through-the-Roof Installation + 2 + 3 + 4 =Min Chimney Components Component Description Model NumberCeramic Refractory Installation Glass Frame Assembly RemovalGlass Cleaning Clean the glass after the first two weeks of operationLog, Lava Rock and Ember Placement DVT38Sw log identificationLog Pilot Plumbing F50 Overlay is very fragile Log Right Flame Characteristics Trim Installation Lighting Instructions Lighting & Operating InstructionsTurning Off the Gas to the Appliance American Flame Gas Control System TroubleshootingOperation Troubleshooting American Flame Gas Control System American Flame Gas Control System Error Codes What to CheckConversion Procedure Conversion PrecautionsFuel Conversion Instructions Remove pilot orifice Valve Minimum Rate Screw Pilot Flame AdjustmentDVT38S2 Injector Orifice Size Matrix Conversion to LPCleaning the Control System MaintenanceBurner and Burner Compartment DVT38S2 Units GFYW5Q0 DVT38S2 DVT38S2Fuel Conversion Kits Accessories Back-up Battery KitChateau Direct Vent Gas Fireplace Limited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %