Vermont Casting DVT38S2IN American Flame Gas Control System Error Codes, What to Check

Page 37

Chateau™ Direct Vent Gas Fireplace

American Flame Gas Control System Error Codes

Ignition Safety: Protection for Ignition System

Error Code: One beep every one second

Description of Fault: Warn users if the pilot is not successfully ignited in 60 seconds.

How to Clear: Press OFF then ON buttons to re-attempt ignition.

What to Check:

Ensure gas supply is turned on.

Ensure orange/white leads from module are plugged into the “PILOT” connection on the valve body.

Verify the lead from igniter on pilot assembly is connected to the “I” terminal on the module.

Verify lead from flame sensor on pilot assembly is connected to the “S” terminal on the module.

Verify that the black ground lead form the module is connected to a proper ground on the fireplace.

Ensure there is no blockage in the pilot line.

Sensor Safety: Protection for Flame Sensor

Error Code: 4 beeps every one second

Description of Fault: Warn users the pilot flame sensor detects a pilot flame already present when ignition sequence is initiated. This fault will also occur if pilot flame sensor is shorted to ground.

How to Clear: Press OFF then ON buttons to re-attempt normal ignition.

What to Check:

Check if pilot flame is actually present when valve is turned OFF (valve replacement necessary if yes).

Replace pilot assembly.

Replace module.

Thermal Safety: Overheat Protection

Error Code: 4 beeps every two seconds.

Description of Fault: Warn users that the module’s internal temperature has exceeded 170° F (77° C).

How to Clear: Module’s internal temperature must cool to below 160° F (71° C) and then press ON button.

What to Check:

Is module located in unapproved location, too close to burner?

Move to cooler location.

Communication Safety: (NOTE: This feature is only available when transmitter includes an LCD screen).

Error Code: One beep every four seconds.

Description of Fault: Warn users that the transmitter and receiver are not communicating properly.

What to Check:

Verify batteries in both transmitter and receiver are new.

Ensure transmitter is located within 20 feet (6 m) of receiver.

Ensure transmitter is not placed in metal enclosure or laying directly on top of a metal surface as this can interfere with transmission.

20011957

37

Image 37
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Certified To Installation & Operating InstructionsAnsi Z21.50b-2005 / CSA 2.22b-2005 Vented Gas Fireplace Please Review the Following CarefullyStandard Framing Locating Your FireplaceMantels Clearance to CombustiblesFraming and Finishing HearthFinal Finishing Gas SpecificationsGas Inlet and Manifold Pressures Gas Line InstallationHigh Elevations Electrical Junction BoxControl System Control System InstallationChateau Direct Vent Gas Fireplace Special Feature for Cold ClimatesKey Settings Remote Control Transmitter Operating InstructionsIntroduction LCD Liquid Crystal DisplayThermostat Function Manual FunctionCP Childproof Feature Continuous Pilot FeatureSetting LOCK-OUT CP Operational Notes Thermostatic Updating FeatureLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Vertical Termination Horizontal TerminationSidewall Applications Step Sidewall InstallationZero clearance sleeve is only required for combustible walls Always install horizontal venting on a level planeHorizontal length requirement Sidewall Installation with Stationary Glass Facing OutsideInstalling the 38S2VDK Door Installation ProcedureRestrictor Plate Installation Flue Restrictor Plate InstallationFlue Restrictor Plate Guide Typical ApplicationsFlue restrictor plate use in straight up installation + 2 + 3 + 4 = Vertical Through-the-Roof InstallationMin Component Description Model Number Chimney ComponentsGlass Cleaning Glass Frame Assembly RemovalCeramic Refractory Installation Clean the glass after the first two weeks of operationDVT38Sw log identification Log, Lava Rock and Ember PlacementLog Pilot Plumbing F50 Overlay is very fragile Log Right Flame Characteristics Trim Installation Lighting Instructions Lighting & Operating InstructionsTurning Off the Gas to the Appliance American Flame Gas Control System TroubleshootingOperation Troubleshooting American Flame Gas Control System What to Check American Flame Gas Control System Error CodesConversion Procedure Conversion PrecautionsFuel Conversion Instructions Remove pilot orifice DVT38S2 Injector Orifice Size Matrix Pilot Flame AdjustmentValve Minimum Rate Screw Conversion to LPCleaning the Control System MaintenanceBurner and Burner Compartment DVT38S2 Units GFYW5Q0 DVT38S2 DVT38S2Fuel Conversion Kits Back-up Battery Kit AccessoriesChateau Direct Vent Gas Fireplace Product Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings