Vermont Casting DVT38S2IN Flue Restrictor Plate Installation, Flue Restrictor Plate Guide

Page 22

Chateau™ Direct Vent Gas Fireplace

3.Install the two (2) short brackets, using sheet metal screws, at the top right and left corners of the fire- place window frame. (Fig. 26) NOTE: If top corners of the window frame do not have two (2) pre-drilled holes, you must drill these holes per Step 4.

4.For window frames not having pre-drilled holes: Align the short brackets so the edge of the bracket is exactly aligned with the side edge of the fireplace window’s top flange, as shown in Figure 27. Mark the location of the holes using a pencil mark through the bracket holes. Drill 1/8” holes at each of the four

(4)locations. Mount brackets using four (4) sheet metal screws.

5.Set the Vista door assembly provided with your kit in front of the glass frame assembly on the fireplace (the outside side).

6.Have the machine screws provided with the kit within reach.

7.Slide the Vista door assembly over the fireplace win- dow frame aligning the four (4) holes with the four

(4)brackets.

8.Using the machine screws, attach the Vista door to the four (4) brackets. Do not overtighten.

WARNING: The glass frame assembly pro- vided with the fireplace must be left in place for proper operation. Failure to do so could cause property damage and malfunction of the fireplace.

Glass

U-Shaped Bracket

Drill Holes for Vista Door

Assembly

Flange

Here

 

Surround Opening

 

Edge

 

Glass Assembly

 

Frame

Vertical Through-the-Roof

Applications

Use of Restrictor Plate

for Vertical Venting Application

The primary purpose for the vent restrictor is to regain flame height under certain venting conditions as outlined below.

Flue Restrictor Plate Installation

Refer to Page 17 for your venting configuration and combination of restrictor plate requirement.

Flue Restrictor Plate Guide

Typical Applications

NG

LP

SK8DVSK or

 

 

2’ (610mm) vertical,

 

 

2’ (610mm) horizontal

None

None

4’ (1.2m) vertical,

 

4¹⁄” flue

10’ (3m) horizontal,

None

restrictor

8’ (2.4m) vertical

 

 

12’ (3.7m) vertical & greater

6³⁄” flue

6³⁄” flue

 

restrictor

restrictor

Restrictor Plate Installation

 

 

Using the two (2) screws provided along with the flue restictor plate shipped with the logset, fasten the restrictor plate to the firebox top through the front of the unit. (Fig. 28)

Flue Opening

Restrictor

Plate

Sheet Metal

Screws

Glass

KT784

FP1364a

DVT38S2

Use tin snips to cut along outer slots to make 4¹⁄₂” (114 mm) restrictor plate. (Refer to Page 17)

Fig. 27 Vista door top hole locations.

Fig. 28 Restrictor plate location.

NOTE: The joints of the inner pipe (flue pipe) must be taped with 550°F or higher temperature metal adhesive tape that meets the requirements of F.A.R. 25.853(a). High temperature sealant milpack or stove cement of 550°F or higher could be used instead. The joints of The outer pipe (fresh air pipe) must be taped with 315°F or higher temperature metal adhesive tape or the use of high temperature milpack or stove cement would be ap-

22

Image 22
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Ansi Z21.50b-2005 / CSA 2.22b-2005 Vented Gas Fireplace Installation & Operating InstructionsCertified To Please Review the Following CarefullyLocating Your Fireplace Standard FramingClearance to Combustibles MantelsFinal Finishing HearthFraming and Finishing Gas SpecificationsHigh Elevations Gas Line InstallationGas Inlet and Manifold Pressures Electrical Junction BoxControl System Installation Control SystemSpecial Feature for Cold Climates Chateau Direct Vent Gas FireplaceIntroduction Remote Control Transmitter Operating InstructionsKey Settings LCD Liquid Crystal DisplayManual Function Thermostat FunctionCP Childproof Feature Continuous Pilot FeatureSetting LOCK-OUT CP Thermostatic Updating Feature Operational NotesGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationUSA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Vertical Termination Horizontal TerminationSidewall Applications Sidewall Installation StepAlways install horizontal venting on a level plane Zero clearance sleeve is only required for combustible wallsSidewall Installation with Stationary Glass Facing Outside Horizontal length requirementInstallation Procedure Installing the 38S2VDK DoorFlue Restrictor Plate Guide Flue Restrictor Plate InstallationRestrictor Plate Installation Typical ApplicationsFlue restrictor plate use in straight up installation Vertical Through-the-Roof Installation + 2 + 3 + 4 =Min Chimney Components Component Description Model NumberCeramic Refractory Installation Glass Frame Assembly RemovalGlass Cleaning Clean the glass after the first two weeks of operationLog, Lava Rock and Ember Placement DVT38Sw log identificationLog Pilot Plumbing F50 Overlay is very fragile Log Right Flame Characteristics Trim Installation Lighting Instructions Lighting & Operating InstructionsTurning Off the Gas to the Appliance American Flame Gas Control System TroubleshootingOperation Troubleshooting American Flame Gas Control System American Flame Gas Control System Error Codes What to CheckConversion Procedure Conversion PrecautionsFuel Conversion Instructions Remove pilot orifice Valve Minimum Rate Screw Pilot Flame AdjustmentDVT38S2 Injector Orifice Size Matrix Conversion to LPCleaning the Control System MaintenanceBurner and Burner Compartment DVT38S2 Units GFYW5Q0 DVT38S2 DVT38S2Fuel Conversion Kits Accessories Back-up Battery KitChateau Direct Vent Gas Fireplace Limited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %