Trace Oxygen Analyzer

Specific Model Information

The instrument for which this manual was supplied may incorporate one or more options not supplied in the standard instrument. Commonly available options are listed below, with check boxes. Any that are incorporated in the instrument for which this manual was supplied are indicated by a check mark in the box.

Instrument Serial Number: __________________________

The instrument with the above serial number has the following Options:

3020T-C

Three gas inputs, for sample, zero and span gases, with

 

three solenoid-actuated gas-flow control valves built in.

 

Valves are automatically synchronized to the analyzer's

 

electronic control sequences.

3020T–FBuilt-in flame arresters for Groups C and D service.

3020T–GBuilt-in flame arresters for Groups C and D service, plus

gas-control valves as in –C option, above.

3020T–HBuilt-in flame arresters for Group B (hydrogen) service.

3020T–I

Built-in flame arresters for Group B (hydrogen) service,

 

plus gas-control valves as in –C option, above.

19" Rack Mount

The 19" Relay Rack Mount units are available with either one or two series 3000 analyzer Control Units installed in a standard 19" panel and ready to mount in a standard rack. See Appendix for details.

Cell Class* ____________________ (L-2C standard).

Enter Class Designation

*See Part II, Chapter 2 and/or any addendum that may be attached to this manual for cell specifications.

Teledyne Analytical Instruments

iii

Image 3
Contents Teledyne Analytical Instruments Model 3020TCopyright 1999 Teledyne Analytical Instruments Model 3020T3020T-I Trace Oxygen AnalyzerIii Specific Model InformationTable of Contents Introduction InstallationOperational Theory Operation MaintenanceAppendix Typical Applications Main Features of the AnalyzerTrace Oxygen Analyzer Introduction OverviewModel 3020T Model DesignationsTrace Oxygen Analyzer Introduction Operator Interface Model 3020T Controls, Indicators, and Connectors1 UP/DOWN Switch ESCAPE/ENTER SwitchPWD Displays Electrical Connector PanelRecognizing Difference Between LCD Equipment InterfaceRemote Valves RS-232 PortGas Connector Panel Remote SensorNetwork I/O Optional Operational Theory Introduction Micro-Fuel Cell SensorPrinciples of Operation Anatomy of a Micro-Fuel Cell Operational Theory+ 2H 2O + 4e → 4OH Electrochemical ReactionsEffect of Pressure Calibration CharacteristicsSample System Characteristic Input/Output Curve for a Micro-Fuel CellSpan Zero Sample Electronics and Signal ProcessingBlock Diagram of the Model 3020T Electronics Temperature Control Trace Oxygen Analyzer Installation Unpacking the AnalyzerMounting the Analyzer Front View of the Model 3020T Simplified Required Front Door Clearance Electrical ConnectionsPrimary Input Power Fuse InstallationAnalog Outputs Analog Output Connections ExamplesRange Voltage Current mA Alarm RelaysTypes of Relay Contacts Digital Remote Cal InputsZero RS-232 Sig RS-232 Pin Purpose Range ID RelaysNetwork I/O 8 RS-232 PortCommand Description Parameter SettingRemote Sensor and Solenoid Valves Remote Solenoid Return Connector Pinouts Installing the Micro-Fuel CellGas Connections Gas Connector Panel Testing the System Using the Controls Trace Oxygen Analyzer OperationAuto Ranging on Analysis Mode Setup ModeMode/Function Selection Trace Oxygen Analyzer Data Entry EnterEscape Trace Oxygen Analyzer Operation AUTO-CALFunction PWD Password FunctionEntering the Password Only one password can be definedInstalling or Changing the Password Version Screen Logout FunctionZero and Span Functions Trace Oxygen Analyzer Operation SELF-TESTFunctionZero Cal Auto Mode ZeroingManual Mode Zeroing Auto Mode Spanning Cell FailureSpan Cal Manual Mode Spanning Installation Alarms FunctionAL-1 AL-2 Choose Alarm Range Function Setting the Analog Output RangesFixed Range Analysis Standby Function Contrast FunctionAnalysis Mode Operation Trace Oxygen Analyzer Maintenance Routine MaintenanceMajor Internal Components Major Internal Components Cell ReplacementWhen to Replace a Cell Storing and Handling Replacement CellsRemoving the Micro-Fuel Cell Exploded View of Cell Block and Micro-Fuel Cell Installing a New Micro-Fuel Cell Fuse Replacement Cell WarrantyL-2C cell is not designed for applications where CO2 is a Removing Fuse Cap and Fuse from Holder System Self Diagnostic TestPower AnalogPreamp Maintenance Trace Oxygen Analyzer Appendix SpecificationsOperating Temperature 0-50 C Qty Part Number Description Recommended 2-Year Spare Parts ListDrawing List Series Analyzers Restrictor KIT Conversions