Panasonic
CU-C24KKS, CU-C18KKS, CS-C18KKS, CS-C24KKS
dimensions
Main Printed Circuit Board
Troubleshooting
Specifications
Operation Characteristics
Install
Refrigeration Cycle Diagram
Timer Control
Connecting the Piping
Dimension
Reset RC Button
Safety Precautions
Page 17
10. Printed Circuit Board
10.1 Indoor Unit
10.1.1
Main Printed Circuit Board
17
Page 16
Page 18
Image 17
Page 16
Page 18
Contents
CS-C18KKS CU-C18KKS CS-C24KKS CU-C24KKS
Exploded View and Replacement Parts List..63
Safety Precautions
Page
Saso T3 Saso T1
Specification
FPI
Features
Location of Controls and Components
Indoor Unit Outdoor Unit Remote Control
Indoor Unit
Dimensions
Outdoor Unit
Refrigeration Cycle Diagram
Block Diagram
CS-C18KKS CU-C18KKS
Wiring Connection Diagram
CS-C24KKS CU-C24KKS
Electronic Circuit Diagram
CS-C24KKS CU-C24KKS
Main Printed Circuit Board
Printed Circuit Board
Power Printed Circuit Board
Page
Indoor/Outdoor Unit Installation Diagram
Installation Instruction
Select the Best Location
Indoor Unit
To Drill a Hole in the Wall and Install a Sleeve of Piping
How to Fix Installation Plate
Indoor Unit Installation
Connect the Cable to the Indoor Unit
Cutting and flaring the piping
Wire Stripping And Connecting Requirement
Connecting the Piping
Install the Outdoor Unit
Evacuation of the Equipment
Connect the cable to the Outdoor Unit
Air Purging of the Piping and Indoor
Pipe Insulation
Cooling Operation
Cooling Operation Time Diagram
Operation Control
Soft Dry Operation
Soft Dry Operation Time Diagram
Automatic Operation
Automatic Fan Speed Control
Fan Speed Rotation Chart
Indoor Fan Speed Control
Indoor Fan Motor rpm Abnormal Control
Manual Fan Speed Control
Vertical Airflow Direction Control
Outdoor Fan Speed Control
Auto Control
Manual Control
Horizontal Airflow Direction Control
Powerful Operation
Quiet Operation
Remote Control Signal Receiving Sound
Timer Control
On Timer
OFF Timer
Transmit check code BuzzerShort Beep
Patrol Operation
Rpm shift
Patrol LED ION Timer
Blue
Ion operation
Press continously for 15s
Page
ECO Patrol Operation
Press continously for 15s
ECO 2 Operation
Press continously for 15s
Protection Control
Restart Control Time Delay Safety Control
13.2 7 Minutes Time Save Control
13.3 60 Seconds Forced Operation
Dew Prevention Control
Freeze Prevention Control
Compressor Reverse Rotation Protection Control
Auto OFF/ON Button
Servicing Mode
Reset RC Button
Remote Control Button
Timer
SET Button
Refrigeration cycle system
Troubleshooting Guide
High Pressure
Diagnosis methods of a malfunction of a compressor
To remove front grille To remove horizontal vane
Disassembly and Assembly Instructions
To remove power electronic controller
Page
Page
CS-C18KKS CU-C18KKS
Technical Data
Operation Characteristics
Piping Length m
CS-C24KKS CU-C24KKS
220V
Exploded View and Replacement Parts List
CS-C24KKS
Drain Hose
Outdoor Unit
SSYW1006-00
Related pages
Troubleshooting for Samsung VC20AVMDCRD/SV
Technical Specifications for Bionaire BCH3620CN08EFM1
Alfcp Alarm Fault Code Print for Dialogic SS7G2X
The EAP-FAST XML Schema, page The PEAP-GTC XML Schema, page for Cisco Systems CB21AG
When the noise suddenly increases Filter for Samsung VCR8825T3R/XEO
Hardware Connections Follow the Quick Installation Guide for Belkin PM00781EA F5D8635-4
Parts List for Linear DC101
Additional information Language code list for Pioneer DV-393-S
To set the Ldap bind password for Lantronix SLC 8000
Why is the
Samsung SWA-8000S not working properly
?
Top
Page
Image
Contents