Panasonic CU-C24KKS, CU-C18KKS, CS-C18KKS Troubleshooting Guide, Refrigeration cycle system

Page 53

15. Troubleshooting Guide

15.1 Refrigeration cycle system

In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include insufficient insulation, problem with the power source, malfunction of a compressor and a fan. The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions, the standard values for them are shown in the table to the right.

Normal Pressure and Outlet Air Temperature (Standard)

 

Gas Pressure

 

Outlet air

 

Mpa

 

Temperature

 

(kg/cm2G)

 

(°C)

Cooling Mode

0.4 ~ 0.6 (4 ~ 6)

 

12 ~ 16

 

 

 

 

Condition: Indoor fan speed = High

 

Outdoor temperature = 35°C

 

Different in the intake

 

 

 

Measuring the air

and outlet

 

 

Normal

 

 

 

temperature different

air temperatures

More than 8°C

 

 

 

 

 

 

 

 

 

 

(15 minutes after an

 

 

 

 

operation is started)

 

 

 

Less than 8°C at the cooling mode

 

 

 

Value of electric current

Higher than specified

Dusty condenser

Measuring electric current

 

 

during operation

 

 

preventing heat radiation

 

during operation

 

 

 

Excessive amount

 

 

 

 

 

of refrigerant

 

 

Lower than specified

 

 

 

 

 

Cooling

High

 

 

 

Gas side

Mode

Inefficient compressor

Measuring gas side

 

 

pressure

 

 

 

 

pressure

 

 

Low

Insufficient refrigerant

 

 

 

 

 

 

 

 

 

Low

Clogged strainer or

 

 

 

 

 

capillary cube

 

 

 

 

 

53

 

 

Image 53
Contents CS-C18KKS CU-C18KKS CS-C24KKS CU-C24KKS Exploded View and Replacement Parts List..63 Safety Precautions Page Saso T3 Saso T1 SpecificationFPI Features Location of Controls and Components Indoor Unit Outdoor Unit Remote ControlIndoor Unit DimensionsOutdoor Unit Refrigeration Cycle Diagram Block Diagram CS-C18KKS CU-C18KKS Wiring Connection DiagramCS-C24KKS CU-C24KKS Electronic Circuit Diagram CS-C24KKS CU-C24KKS Main Printed Circuit Board Printed Circuit BoardPower Printed Circuit Board Page Indoor/Outdoor Unit Installation Diagram Installation InstructionSelect the Best Location Indoor UnitTo Drill a Hole in the Wall and Install a Sleeve of Piping How to Fix Installation PlateIndoor Unit Installation Connect the Cable to the Indoor Unit Cutting and flaring the piping Wire Stripping And Connecting RequirementConnecting the Piping Install the Outdoor UnitEvacuation of the Equipment Connect the cable to the Outdoor Unit Air Purging of the Piping and IndoorPipe Insulation Cooling Operation Cooling Operation Time DiagramOperation Control Soft Dry Operation Soft Dry Operation Time DiagramAutomatic Operation Automatic Fan Speed Control Fan Speed Rotation ChartIndoor Fan Speed Control Indoor Fan Motor rpm Abnormal Control Manual Fan Speed ControlVertical Airflow Direction Control Outdoor Fan Speed ControlAuto Control Manual ControlHorizontal Airflow Direction Control Powerful OperationQuiet Operation Remote Control Signal Receiving Sound Timer ControlOn Timer OFF TimerTransmit check code BuzzerShort Beep Patrol OperationRpm shift Patrol LED ION Timer Blue Ion operation Press continously for 15s Page ECO Patrol Operation Press continously for 15s ECO 2 Operation Press continously for 15s Protection Control Restart Control Time Delay Safety Control13.2 7 Minutes Time Save Control 13.3 60 Seconds Forced OperationDew Prevention Control Freeze Prevention ControlCompressor Reverse Rotation Protection Control Auto OFF/ON Button Servicing ModeReset RC Button Remote Control ButtonTimer SET ButtonRefrigeration cycle system Troubleshooting GuideHigh Pressure Diagnosis methods of a malfunction of a compressorTo remove front grille To remove horizontal vane Disassembly and Assembly InstructionsTo remove power electronic controller Page Page CS-C18KKS CU-C18KKS Technical DataOperation Characteristics Piping Length m CS-C24KKS CU-C24KKS 220V Exploded View and Replacement Parts List CS-C24KKS Drain Hose Outdoor Unit SSYW1006-00