12.4 Indoor Fan Speed Control
•Indoor fan speed can be set using remote control.
12.4.1Fan Speed Rotation Chart
Speed |
| Fan Speed (rpm) | |
| |||
|
| ||
Shi | 1370 |
| 1500 |
Hi | 1200 |
| 1350 |
Me | 1110 |
| 1230 |
HLo | 1080 |
| 1190 |
CLo | 1020 |
| 1110 |
Lo- | 850 |
| 970 |
SLo | 670 |
| 750 |
Qhi | 1110 |
| 1150 |
QMe | 1020 |
| 1050 |
QLo | 930 |
| 960 |
12.4.2Automatic Fan Speed Control
•When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table.
o Fan speed rotates in the range of Hi, Me and
|
|
|
|
| SHi | Hi | Me | HLo | CLo | Lo- | SLo | Stop |
|
| Manual |
| Hi |
| o |
|
|
|
|
|
|
| Normal |
| Me |
|
| o |
|
|
|
|
| |
|
|
| Lo |
|
|
|
| o |
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||
Cooling |
| Auto |
|
|
| o | o |
|
| o |
| o |
| Manual |
| QHi |
|
|
|
|
|
|
| ||
Quiet |
| QMe |
|
|
|
|
|
|
| |||
|
| QLo |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||
|
| Auto |
|
|
|
|
| o |
| o | ||
| Powerful | Manual | o |
|
|
|
|
|
|
| ||
| Auto |
| o |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |||
Dry | Normal | Manual |
|
|
|
|
| o |
| o | ||
Auto |
|
|
|
|
|
| o |
| o | |||
Soft | Quiet | Manual |
|
|
|
|
| o |
| o | ||
|
|
|
|
|
| o |
| o | ||||
|
| Auto |
|
|
|
|
|
|
|
32