WARNING

20.After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant contacts with fire.

21.Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire.

22.Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.

23.Must not use other parts except original parts described in catalog and manual.

CAUTION

1.Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire.

2.Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture.

3.Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage.

4. Do not touch outdoor unit air inlet and aluminium fin. It may cause injury.

5.Select an installation location which is easy for maintenance.

6.Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).

Pb free solder will tend to splash when heated too high (about 1100°F / 600°C).

7.Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following methods.

Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, permanent connection of this room air conditioner to the power supply is prohibited.

i.Power supply connection to the receptacle using a power plug. Use an approved 15/16A (3/4~1.5HP) or 16A (2.0HP) or 20A (2.5HP) or 25A (3.0HP) power plug with earth pin for the connection to the socket.

ii.Power supply connection to a circuit breaker for the permanent component. Use an approved 16A (3/4~2.0HP) or 20A (2.5HP) or

25A (3.0HP) circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap.

8.Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. Take care of the liquid refrigerant, it may cause frostbite.

9.Installation or servicing work: It may need two people to carry out the installation or servicing work.

10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.

11. Do not sit or step on the unit, you may fall down accidentally.

12.Do not touch the sharp aluminum fins or edges of metal parts.

If you are required to handle sharp parts during installation or servicing, please wear hand glove. Sharp parts may cause injury.

4

Image 4
Contents CS-C18KKS CU-C18KKS CS-C24KKS CU-C24KKS Exploded View and Replacement Parts List..63 Safety Precautions Page Specification Saso T3 Saso T1FPI Features Indoor Unit Outdoor Unit Remote Control Location of Controls and ComponentsDimensions Indoor UnitOutdoor Unit Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram CS-C18KKS CU-C18KKSCS-C24KKS CU-C24KKS Electronic Circuit Diagram CS-C24KKS CU-C24KKS Printed Circuit Board Main Printed Circuit BoardPower Printed Circuit Board Page Installation Instruction Indoor/Outdoor Unit Installation DiagramSelect the Best Location Indoor UnitHow to Fix Installation Plate To Drill a Hole in the Wall and Install a Sleeve of PipingIndoor Unit Installation Connect the Cable to the Indoor Unit Wire Stripping And Connecting Requirement Cutting and flaring the pipingInstall the Outdoor Unit Connecting the PipingEvacuation of the Equipment Air Purging of the Piping and Indoor Connect the cable to the Outdoor UnitPipe Insulation Operation Control Cooling Operation Time DiagramCooling Operation Soft Dry Operation Time Diagram Soft Dry OperationAutomatic Operation Indoor Fan Speed Control Fan Speed Rotation ChartAutomatic Fan Speed Control Manual Fan Speed Control Indoor Fan Motor rpm Abnormal ControlOutdoor Fan Speed Control Vertical Airflow Direction ControlAuto Control Manual ControlPowerful Operation Horizontal Airflow Direction ControlQuiet Operation Timer Control Remote Control Signal Receiving SoundOn Timer OFF TimerPatrol Operation Transmit check code BuzzerShort BeepRpm shift Patrol LED ION Timer Blue Ion operation Press continously for 15s Page ECO Patrol Operation Press continously for 15s ECO 2 Operation Press continously for 15s Restart Control Time Delay Safety Control Protection Control13.2 7 Minutes Time Save Control 13.3 60 Seconds Forced OperationCompressor Reverse Rotation Protection Control Freeze Prevention ControlDew Prevention Control Servicing Mode Auto OFF/ON ButtonRemote Control Button Reset RC ButtonTimer SET ButtonTroubleshooting Guide Refrigeration cycle systemDiagnosis methods of a malfunction of a compressor High PressureDisassembly and Assembly Instructions To remove front grille To remove horizontal vaneTo remove power electronic controller Page Page Operation Characteristics Technical DataCS-C18KKS CU-C18KKS Piping Length m CS-C24KKS CU-C24KKS 220V Exploded View and Replacement Parts List CS-C24KKS Drain Hose Outdoor Unit SSYW1006-00