11.3.6Pipe Insulation

1Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap the insulated piping end to prevent water from going inside the piping.

2If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E-FOAM with thickness 6mm or above.

28

Image 28
Contents CS-C18KKS CU-C18KKS CS-C24KKS CU-C24KKS Exploded View and Replacement Parts List..63 Safety Precautions Page Specification Saso T3 Saso T1FPI Features Indoor Unit Outdoor Unit Remote Control Location of Controls and ComponentsDimensions Indoor UnitOutdoor Unit Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram CS-C18KKS CU-C18KKSCS-C24KKS CU-C24KKS Electronic Circuit Diagram CS-C24KKS CU-C24KKS Printed Circuit Board Main Printed Circuit BoardPower Printed Circuit Board Page Installation Instruction Indoor/Outdoor Unit Installation DiagramSelect the Best Location Indoor UnitHow to Fix Installation Plate To Drill a Hole in the Wall and Install a Sleeve of PipingIndoor Unit Installation Connect the Cable to the Indoor Unit Wire Stripping And Connecting Requirement Cutting and flaring the pipingInstall the Outdoor Unit Connecting the PipingEvacuation of the Equipment Air Purging of the Piping and Indoor Connect the cable to the Outdoor UnitPipe Insulation Operation Control Cooling Operation Time DiagramCooling Operation Soft Dry Operation Time Diagram Soft Dry OperationAutomatic Operation Indoor Fan Speed Control Fan Speed Rotation ChartAutomatic Fan Speed Control Manual Fan Speed Control Indoor Fan Motor rpm Abnormal ControlOutdoor Fan Speed Control Vertical Airflow Direction ControlAuto Control Manual ControlPowerful Operation Horizontal Airflow Direction ControlQuiet Operation Timer Control Remote Control Signal Receiving SoundOn Timer OFF TimerPatrol Operation Transmit check code BuzzerShort BeepRpm shift Patrol LED ION Timer Blue Ion operation Press continously for 15s Page ECO Patrol Operation Press continously for 15s ECO 2 Operation Press continously for 15s Restart Control Time Delay Safety Control Protection Control13.2 7 Minutes Time Save Control 13.3 60 Seconds Forced OperationCompressor Reverse Rotation Protection Control Freeze Prevention ControlDew Prevention Control Servicing Mode Auto OFF/ON ButtonRemote Control Button Reset RC ButtonTimer SET ButtonTroubleshooting Guide Refrigeration cycle systemDiagnosis methods of a malfunction of a compressor High PressureDisassembly and Assembly Instructions To remove front grille To remove horizontal vaneTo remove power electronic controller Page Page Operation Characteristics Technical DataCS-C18KKS CU-C18KKS Piping Length m CS-C24KKS CU-C24KKS 220V Exploded View and Replacement Parts List CS-C24KKS Drain Hose Outdoor Unit SSYW1006-00