Panasonic CU-C18KKS, CU-C24KKS, CS-C18KKS, CS-C24KKS dimensions Piping Length m

Page 60

Piping Length Characteristic

oOutdoor temperature: 35°C (DBT), 24°C (WBT)

o

Operation condition:

High fan speed

o

Piping length:

5.0m

220V

 

7.90

(A)

7.80

7.70

Current

7.60

7.50

 

 

7.40

7.30

7.20

3

5

7

9

11

13

15

17

19

21

23

25

 

 

 

 

 

Piping Length (m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

220V

 

 

(MPa)

0.500

 

 

 

 

 

 

 

 

 

 

 

 

0.490

 

 

 

 

 

 

 

 

 

 

 

Gas Side

0.480

 

 

 

 

 

 

 

 

 

 

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

0.470

 

 

 

 

 

 

 

 

 

 

 

0.460

 

 

 

 

 

 

 

 

 

 

 

0.450

 

 

 

 

 

 

 

 

 

 

 

 

Piping

 

 

 

 

 

 

 

 

 

 

 

 

0.440

 

 

 

 

 

 

 

 

 

 

 

 

0.430

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

5

7

9

11

13

15

17

19

21

23

25

Piping Length (m)

Capacity (kW)

220V

5.20

5.10

5.00

4.90

4.80

4.70

4.60

4.50

3

5

7

9

11

13

15

17

19

21

23

25

 

 

 

 

 

Piping

Length (m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

220V

 

 

15.3

 

 

 

 

 

 

 

 

 

 

 

(ºC)

15.2

 

 

 

 

 

 

 

 

 

 

 

15.1

 

 

 

 

 

 

 

 

 

 

 

15.0

 

 

 

 

 

 

 

 

 

 

 

Air

 

 

 

 

 

 

 

 

 

 

 

14.9

 

 

 

 

 

 

 

 

 

 

 

Outlet

 

 

 

 

 

 

 

 

 

 

 

14.8

 

 

 

 

 

 

 

 

 

 

 

14.7

 

 

 

 

 

 

 

 

 

 

 

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

14.5

 

 

 

 

 

 

 

 

 

 

 

 

3

5

7

9

11

13

15

17

19

21

23

25

Piping Length (m)

60

Image 60
Contents CS-C18KKS CU-C18KKS CS-C24KKS CU-C24KKS Exploded View and Replacement Parts List..63 Safety Precautions Page Specification Saso T3 Saso T1FPI Features Indoor Unit Outdoor Unit Remote Control Location of Controls and ComponentsDimensions Indoor UnitOutdoor Unit Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram CS-C18KKS CU-C18KKSCS-C24KKS CU-C24KKS Electronic Circuit Diagram CS-C24KKS CU-C24KKS Printed Circuit Board Main Printed Circuit BoardPower Printed Circuit Board Page Installation Instruction Indoor/Outdoor Unit Installation DiagramSelect the Best Location Indoor UnitHow to Fix Installation Plate To Drill a Hole in the Wall and Install a Sleeve of PipingIndoor Unit Installation Connect the Cable to the Indoor Unit Wire Stripping And Connecting Requirement Cutting and flaring the pipingInstall the Outdoor Unit Connecting the PipingEvacuation of the Equipment Air Purging of the Piping and Indoor Connect the cable to the Outdoor UnitPipe Insulation Cooling Operation Time Diagram Operation ControlCooling Operation Soft Dry Operation Time Diagram Soft Dry OperationAutomatic Operation Fan Speed Rotation Chart Indoor Fan Speed ControlAutomatic Fan Speed Control Manual Fan Speed Control Indoor Fan Motor rpm Abnormal ControlOutdoor Fan Speed Control Vertical Airflow Direction ControlAuto Control Manual ControlPowerful Operation Horizontal Airflow Direction ControlQuiet Operation Timer Control Remote Control Signal Receiving SoundOn Timer OFF TimerPatrol Operation Transmit check code BuzzerShort BeepRpm shift Patrol LED ION Timer Blue Ion operation Press continously for 15s Page ECO Patrol Operation Press continously for 15s ECO 2 Operation Press continously for 15s Restart Control Time Delay Safety Control Protection Control13.2 7 Minutes Time Save Control 13.3 60 Seconds Forced OperationFreeze Prevention Control Compressor Reverse Rotation Protection ControlDew Prevention Control Servicing Mode Auto OFF/ON ButtonRemote Control Button Reset RC ButtonTimer SET ButtonTroubleshooting Guide Refrigeration cycle systemDiagnosis methods of a malfunction of a compressor High PressureDisassembly and Assembly Instructions To remove front grille To remove horizontal vaneTo remove power electronic controller Page Page Technical Data Operation CharacteristicsCS-C18KKS CU-C18KKS Piping Length m CS-C24KKS CU-C24KKS 220V Exploded View and Replacement Parts List CS-C24KKS Drain Hose Outdoor Unit SSYW1006-00