Panasonic CS-C18KKS, CU-C18KKS, CU-C24KKS, CS-C24KKS dimensions Ion operation

Page 42

12.14E-ion operation

This operation provides clean air by producing negative ions to attract dust captured at the positively charged active e-ion filters.

e-ion operation start condition

o During unit running at any operation mode, if “e-ion” operation is selected, combination operation (operation mode + e-ion operation) starts.

o During unit is OFF, if “e-ion” operation is selected, e-ion individual operation starts.

e-ion operation stop condition

o When “OFF/ON” button is pressed to stop the operation. o When “PATROL/e-ion” button is pressed.

o When OFF Timer activates.

e-ion operation pause condition

o When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after indoor fan restarts.

o When indoor intake temperature ≥ 40°C. e-ion operation resume after indoor intake temperature < 40°C continuously for 30 minutes.

Indoor fan control

o During any operation mode combines with e-ion operation, fan speed follows respective operation mode. o During e-ion individual operation – only Auto Fan Speed and no Powerful operation is allowed. Even if Fan

Speed button is pressed, no signal is sent to air conditioner, and no change on LCD display.

Auto Fan Speed for e-ion operation switches from SHi to Hi after 4 hours of operation.

Airflow direction control

o During any operation mode combines with e-ion operation, airflow direction follows respective operation mode.

o During e-ion individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no signal is sent to air conditioner, and no change on LCD display.

Timer control

o When ON timer activates when unit stops, previous operation resumes and restored last saved e-ion operation status.

o When ON timer activates during any operation, no change and carry on current operation.

o When OFF timer activates during any operation, all operation stops and the latest e-ion operation status is saved.

Indicator

o When e-ion operation starts, e-ion indicator ON.

Remote Control Receiving Sound

o

Normal Operation

Î e-ion Operation

: Beep

o

e-ion Operation

Î Normal Operation

: Beep

o

Stop

Î e-ion individual Operation

: Beep

o

e-ion individual Operation

Î Stop

: Long Beep

Power failure

o During e-ion individual operation, if power failure occurs, after power resumes, e-ion individual operation resumes immediately.

o During combination operation, if power failure occurs, after power resumes, combination operation resume immediately.

o e-ion operation status is not memorized after OFF the unit. After OFF, when the operation is ON again, air conditioner operates without e-ion operation.

42

Image 42
Contents CS-C18KKS CU-C18KKS CS-C24KKS CU-C24KKS Exploded View and Replacement Parts List..63 Safety Precautions Page Specification Saso T3 Saso T1FPI Features Indoor Unit Outdoor Unit Remote Control Location of Controls and ComponentsDimensions Indoor UnitOutdoor Unit Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram CS-C18KKS CU-C18KKSCS-C24KKS CU-C24KKS Electronic Circuit Diagram CS-C24KKS CU-C24KKS Printed Circuit Board Main Printed Circuit BoardPower Printed Circuit Board Page Select the Best Location Installation InstructionIndoor/Outdoor Unit Installation Diagram Indoor UnitHow to Fix Installation Plate To Drill a Hole in the Wall and Install a Sleeve of PipingIndoor Unit Installation Connect the Cable to the Indoor Unit Wire Stripping And Connecting Requirement Cutting and flaring the pipingInstall the Outdoor Unit Connecting the PipingEvacuation of the Equipment Air Purging of the Piping and Indoor Connect the cable to the Outdoor UnitPipe Insulation Cooling Operation Time Diagram Operation ControlCooling Operation Soft Dry Operation Time Diagram Soft Dry OperationAutomatic Operation Fan Speed Rotation Chart Indoor Fan Speed ControlAutomatic Fan Speed Control Manual Fan Speed Control Indoor Fan Motor rpm Abnormal ControlAuto Control Outdoor Fan Speed ControlVertical Airflow Direction Control Manual ControlPowerful Operation Horizontal Airflow Direction ControlQuiet Operation On Timer Timer ControlRemote Control Signal Receiving Sound OFF TimerPatrol Operation Transmit check code BuzzerShort BeepRpm shift Patrol LED ION Timer Blue Ion operation Press continously for 15s Page ECO Patrol Operation Press continously for 15s ECO 2 Operation Press continously for 15s 13.2 7 Minutes Time Save Control Restart Control Time Delay Safety ControlProtection Control 13.3 60 Seconds Forced OperationFreeze Prevention Control Compressor Reverse Rotation Protection ControlDew Prevention Control Servicing Mode Auto OFF/ON ButtonTimer Remote Control ButtonReset RC Button SET ButtonTroubleshooting Guide Refrigeration cycle systemDiagnosis methods of a malfunction of a compressor High PressureDisassembly and Assembly Instructions To remove front grille To remove horizontal vaneTo remove power electronic controller Page Page Technical Data Operation CharacteristicsCS-C18KKS CU-C18KKS Piping Length m CS-C24KKS CU-C24KKS 220V Exploded View and Replacement Parts List CS-C24KKS Drain Hose Outdoor Unit SSYW1006-00