Panasonic CS-C24KKS, CU-C18KKS, CU-C24KKS Exploded View and Replacement Parts List, Indoor Unit

Page 63

18. Exploded View and Replacement Parts List

18.1 Indoor Unit

Note

The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.

63

Image 63
Contents CS-C18KKS CU-C18KKS CS-C24KKS CU-C24KKS Exploded View and Replacement Parts List..63 Safety Precautions Page Saso T3 Saso T1 SpecificationFPI Features Location of Controls and Components Indoor Unit Outdoor Unit Remote ControlIndoor Unit DimensionsOutdoor Unit Refrigeration Cycle Diagram Block Diagram CS-C18KKS CU-C18KKS Wiring Connection DiagramCS-C24KKS CU-C24KKS Electronic Circuit Diagram CS-C24KKS CU-C24KKS Main Printed Circuit Board Printed Circuit BoardPower Printed Circuit Board Page Indoor Unit Installation InstructionIndoor/Outdoor Unit Installation Diagram Select the Best LocationTo Drill a Hole in the Wall and Install a Sleeve of Piping How to Fix Installation PlateIndoor Unit Installation Connect the Cable to the Indoor Unit Cutting and flaring the piping Wire Stripping And Connecting RequirementConnecting the Piping Install the Outdoor UnitEvacuation of the Equipment Connect the cable to the Outdoor Unit Air Purging of the Piping and IndoorPipe Insulation Cooling Operation Time Diagram Operation ControlCooling Operation Soft Dry Operation Soft Dry Operation Time DiagramAutomatic Operation Fan Speed Rotation Chart Indoor Fan Speed ControlAutomatic Fan Speed Control Indoor Fan Motor rpm Abnormal Control Manual Fan Speed ControlManual Control Outdoor Fan Speed ControlVertical Airflow Direction Control Auto ControlHorizontal Airflow Direction Control Powerful OperationQuiet Operation OFF Timer Timer ControlRemote Control Signal Receiving Sound On TimerTransmit check code BuzzerShort Beep Patrol OperationRpm shift Patrol LED ION Timer Blue Ion operation Press continously for 15s Page ECO Patrol Operation Press continously for 15s ECO 2 Operation Press continously for 15s 13.3 60 Seconds Forced Operation Restart Control Time Delay Safety ControlProtection Control 13.2 7 Minutes Time Save ControlFreeze Prevention Control Compressor Reverse Rotation Protection ControlDew Prevention Control Auto OFF/ON Button Servicing ModeSET Button Remote Control ButtonReset RC Button TimerRefrigeration cycle system Troubleshooting GuideHigh Pressure Diagnosis methods of a malfunction of a compressorTo remove front grille To remove horizontal vane Disassembly and Assembly InstructionsTo remove power electronic controller Page Page Technical Data Operation CharacteristicsCS-C18KKS CU-C18KKS Piping Length m CS-C24KKS CU-C24KKS 220V Exploded View and Replacement Parts List CS-C24KKS Drain Hose Outdoor Unit SSYW1006-00