Error Detection Control

When e-ion indicator blink, it indicates error listed below:

o Active e-ion Air Purifying system PCB main connector open:

ƒJudgment Method

During e-ion operation (include during Patrol operation), Active e-ion Air Purifying system main connector to PCB is opened.

ƒTroubleshooting Methods

Connect the connector or stop operation (include during Patrol operation) to cancel the blinking.

oAbnormal Discharge error:

ƒJudgment Method

During e-ion operation, feedback voltage is-Lo (at microcontroller) is detected, it is judged abnormal discharge and stops power supplies to the Active e-ion Air Purifying system.

Abnormal discharge is caused by ionizer or filter’s high voltage power supply short-circuits due to water or dust adhesion, and so forth.

When abnormal discharge occurred, every 30 minutes the unit supplies power to the Active e-ion Air Purifying system.

When abnormal discharge occurs for 24 times continuously, e-ion indicator blinks (not applicable for e-ion Check Mode, where the error will shows immediately despite the 24 times counter)

ƒTroubleshooting Method

Press “PATROL/e-ion” button or “OFF/ON” button to stop the operation and check the Active e-ion Air Purifying system main connector to PCB.

After that, press “e-ion” button again to confirm the e-ion indicator not blinking.

The 24 times counter will be clear after 10 minutes of normal operation or when operation stops.

ƒError Reset Method

Press “OFF/ON” button to OFF the operation.

Press AUTO OFF/ON button at indoor unit to OFF the operation.

OFF Timer activates

Power supply reset

oActive e-ion Air Purifying system breakdown error:

ƒJudgment Method

When hi-feedback voltage (at microcontroller) supplied to filter during e-ion stop, Active e-ion Air Purifying system breakdown error shows immediately.

It is due to indoor PCB or filter’s high voltage power supply damage.

Operations except e-ion continue. Both Timer indicator and e-ion indicator blink.

ƒTroubleshooting Method

Press “PATROL/e-ion” button or “OFF/ON” button to stop the operation.

Change main circuit board or filter’s high voltage power supply.

When lo-feedback voltage supplied to Active e-ion Air Purifying system during e-ion operation, e-ion indicator and Timer indicator stop blinking.

44

Image 44
Contents CS-C18KKS CU-C18KKS CS-C24KKS CU-C24KKS Exploded View and Replacement Parts List..63 Safety Precautions Page Specification Saso T3 Saso T1FPI Features Indoor Unit Outdoor Unit Remote Control Location of Controls and ComponentsDimensions Indoor UnitOutdoor Unit Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram CS-C18KKS CU-C18KKSCS-C24KKS CU-C24KKS Electronic Circuit Diagram CS-C24KKS CU-C24KKS Printed Circuit Board Main Printed Circuit BoardPower Printed Circuit Board Page Installation Instruction Indoor/Outdoor Unit Installation DiagramSelect the Best Location Indoor UnitHow to Fix Installation Plate To Drill a Hole in the Wall and Install a Sleeve of PipingIndoor Unit Installation Connect the Cable to the Indoor Unit Wire Stripping And Connecting Requirement Cutting and flaring the pipingInstall the Outdoor Unit Connecting the PipingEvacuation of the Equipment Air Purging of the Piping and Indoor Connect the cable to the Outdoor UnitPipe Insulation Cooling Operation Cooling Operation Time DiagramOperation Control Soft Dry Operation Time Diagram Soft Dry OperationAutomatic Operation Automatic Fan Speed Control Fan Speed Rotation ChartIndoor Fan Speed Control Manual Fan Speed Control Indoor Fan Motor rpm Abnormal ControlOutdoor Fan Speed Control Vertical Airflow Direction ControlAuto Control Manual ControlPowerful Operation Horizontal Airflow Direction ControlQuiet Operation Timer Control Remote Control Signal Receiving SoundOn Timer OFF TimerPatrol Operation Transmit check code BuzzerShort BeepRpm shift Patrol LED ION Timer Blue Ion operation Press continously for 15s Page ECO Patrol Operation Press continously for 15s ECO 2 Operation Press continously for 15s Restart Control Time Delay Safety Control Protection Control13.2 7 Minutes Time Save Control 13.3 60 Seconds Forced OperationDew Prevention Control Freeze Prevention ControlCompressor Reverse Rotation Protection Control Servicing Mode Auto OFF/ON ButtonRemote Control Button Reset RC ButtonTimer SET ButtonTroubleshooting Guide Refrigeration cycle systemDiagnosis methods of a malfunction of a compressor High PressureDisassembly and Assembly Instructions To remove front grille To remove horizontal vaneTo remove power electronic controller Page Page CS-C18KKS CU-C18KKS Technical DataOperation Characteristics Piping Length m CS-C24KKS CU-C24KKS 220V Exploded View and Replacement Parts List CS-C24KKS Drain Hose Outdoor Unit SSYW1006-00