Adjusting Adjustable Angle Flip-Up Footplates

Depth Adjustment

NOTE: For this procedure, refer to FIGURE 6.9 on page 40.

1.Remove the two flat screws, washers and locknuts that secure footplate to the half clamp.

NOTE: Observe the angle of the footplate for reinstallation.

2. Move footplate to one of four mounting positions.

NOTE: If desired depth is still not obtained, rotate the half clamp on the footplate hinge 180°.

3. Retighten the two flat screws, washers and locknuts.

NOTE: The settings for positioning the footplates on the half-clamps may vary for each footplate.

Angle Adjustment

NOTE: For this procedure, refer to FIGURE 6.9 on page 40 and FIGURE 6.10.

1.Loosen, but DO NOT remove, the two flat screws, washer and locknuts that secure the footplate to the footplate hinge (FIGURE 6.9).

2.Position the footplate to the necessary angle to accommodate the user (FIGURE 6.10).

3.Retighten the two flat screws, washers and locknuts.

 

Side View of

Footrest Support

Footplate and

Footplate

Footrest

Support

 

FIGURE 6.10 Angle Adjustment

Perpendicular and/or Inversion/Eversion Adjustment

NOTE: For this procedure, refer to FIGURE 6.9 on page 40 and FIGURE 6.11.

NOTE: It is not necessary to remove the footplate to perform this adjustment.

1.Insert a flathead screwdriver through the half clamp on the footplate (FIGURE 6.9).

2.Slowly turn nylon adjustment screw in or out until footplate is perpendicular to the footrest assembly or the desired inversion or eversion is obtained (FIGURE 6.11).

Front View of Footplate

and Footrest Support

Footrest Support

Footplate

FIGURE 6.11 Perpendicular and/or

Inversion/Eversion Adjustment

Part No 1122170

41

Formula™ Powered Seating

Image 41
Contents Dealer This manual Must be given to the user of the product Formula Powered SeatingDocument Part Number Reference DocumentsReference Documents Table of Contents Register Your Product Wheelchair TIE-DOWN Restraints and Seat Restraints Trbkts Signal Word MeaningSpecial Notes Powered Seating System Warnings All Wheelchairs Label LocationsWheelchairs with Elevate Wheelchairs with Ventilator Trays Contoura Backs Conventional Formula Powered Seating SystemsTypical Product Parameters Backs Typical Product Parameters Contoura Backs ConventionalOperation Information Repair or Service InformationGeneral Guidelines General Guidelines General Guidelines Weight Limitation Weight TrainingEMI Information EMI InformationEMI Information Pinch Points SAFETY/HANDLING of WheelchairsInspect/Adjust Initially Safety INSPECTION/ TroubleshootingSafety Inspection Checklists Inspect/Adjust Periodically Inspect/Adjust WeeklyInspect/Adjust Monthly Symptom Probable Cause Solutions TroubleshootingJS REV TOO Large Tilt Warning displays Wheelchair Operation Switch Option Through Operating Powered Seating SystemsSystem Type Joystick Powered Seating Control Using the Four Way Switch Using the Powered Seating SwitchSeating System Four WAY Switch RightIcon Description Using the MPJ+ joystickUsing the MPJ+ joystick Speed Control MPJ+ Joystick Switches and IndicatorsDrive Select Toggle Switch LCD Display Screens JoystickCharger/Programming Input LCD Display ECU Wheelchair Operation Icon Programmable Mono Port 1/2 or External Mode SwitchRemote On/Off Switch Memory Card Slot Mode SwitchPreparing the Joystick for Use Repositioning the Joystick PHAL4A, 70 and PW93 Installing/Removing FootrestsFront Riggings PHAL4A Front Riggings Footrest Height AdjustmentTaper PW93 Footrest Height Adjustment PW93Raising/Lowering Elevating Front Riggings Adjusting/Replacing Telescoping Front Rigging SupportAdjusting/Replacing Telescoping Front Rigging Support Installing Adjustable Angle Flip-up Footplates Installing Adjustable Angle Flip-up Footplate HingeDepth Adjustment Adjusting Adjustable Angle Flip-Up FootplatesAngle Adjustment Perpendicular and/or Inversion/Eversion AdjustmentAssembly Composite/Articulating Footplate Heel Loop ReplacementDisassembly Removing Installing/Removing Elevating LegrestsInstalling Raising/Lowering Elevating Legrests Adjusting CalfpadsRemoving/Installing the Center Mount Footrest 15 Removing/Installing the Center Mount Footrest 16 Adjusting the Height of the Center Mount Footrest Adjusting the Height of the Center Mount FootrestAfter 2/14/07 Adjusting the Angle of the Manual Center Mount FootrestAdjusting the Footplate Angle Before 2/15/07 Adjusting the Tension of the Flip Up Footplate21 Calf Pad Adjustment for Power Center Mount Footrests Calf Pad Adjustment for Power Center Mount FootrestsInstalling the Power Elevating Legrests Installing/Removing the Power Elevating LegrestsHeight and Width Adjustment 22 Installing/Removing the Power Elevating Legrests Removing the Power Elevating LegrestsArms Installing/Removing Flip Back ArmrestsAdjusting Adjusting Flip Back ArmrestsPositioning Flip Back Armrests for User Transfer Positioning Flip Back Armrests for UseRemoving Armrests Removing/Installing Reclining ArmrestsInstalling Armrests Adjusting Reclining Armrest Height Adjusting Reclining Armrest Height Seat Adjusting the Back AngleReplacing Seat Positioning Strap Replacing Seat Positioning StrapHeadrest Removing/Installing/Adjusting HeadrestReplacing Headrest Adjusting Headrest HeightAdjusting Headrest Depth/Direction Elevate Batteries Replacing Batteries Using the Proper BatteriesElevate Batteries Replacing Batteries Removing/Installing the Batteries From/Into the Wheelchair Cleaning Battery TerminalsRemoving the Battery Door and Rear Shrouds ImmediatelyRemoving the Battery Door and Rear Shrouds Removing the Batteries Installing BatteriesInstalling Batteries Installing the Battery Door and Rear ShroudCharging Batteries When to Charge BatteriesTool Quantity Comments Description and Use of Battery ChargersCharging Batteries Preparing the Ventilator Tray for Use Ventilator TrayPreparing the Ventilator Tray for Use Global Limited Warranty Excluding Canada Global Limited Warranty Excluding CanadaUSA Canada Limited Warranty