Genie Z-80, Z-60 manual Function Tests, At the Ground Controls, Test Emergency Stop

Page 17

First Edition · Third Printing

Operator's Manual

 

 

 

 

Function Tests

Do Not Operate Unless:

You learn and practice the principles of safe machine operation contained in this operator's manual.

1Avoid hazardous situations.

2Always perform a pre-operation inspection.

3Always perform function tests prior to use.

Know and understand the function tests before going on to the next section.

4Inspect the workplace.

5Only use the machine as it was intended.

Fundamentals

The function tests are designed to discover any malfunctions before the machine is put into service. The operator must follow the step-by-step instructions to test all machine functions.

A malfunctioning machine must never be used. If malfunctions are discovered, the machine must be tagged and removed from service. Repairs to the machine may only be made by a qualified service technician, according to the manufacturer's specifications.

After repairs are completed, the operator must perform a pre-operation inspection and function tests again before putting the machine into service.

1Select a test area that is firm, level and free of obstruction.

At the Ground Controls

2Turn the key switch to ground control.

3Pull out the red Emergency Stop button to the on position.

Result: The LCD screen will come on and display no error messages. The beacon (if equipped) should flash.

Note: In cold climates, the LCD readout screen will need to warm up before the display appears.

4Start the engine. See Operating Instructions section.

Test Emergency Stop

5Push in the red Emergency Stop button to the off position.

Result: The engine should turn off and no functions should operate.

6Pull out the red Emergency Stop button to the on position and restart the engine.

Test the Machine Functions

7Do not press and hold a function enable/speed select button. Attempt to activate each boom and platform function button.

Result: No boom and platform functions should operate.

8Press and hold a function enable /speed select button and activate each boom and platform function button.

Result: All boom and platform functions should operate through a full cycle. The descent alarm (if equipped) should sound while the boom is lowering.

Part No. 82258

Genie Z-80/60

15

Image 17
Contents Operator’s Manual Contact us ContentsDo Not Operate Unless Safety RulesTip-over Hazards Electrocution HazardsSafety Rules Collision Hazards Fall HazardsExplosion and Fire Hazards Component Damage HazardsDecal Legend Damaged Machine HazardsBodily Injury Hazard Ground Control Panel ControlsPlatform Control Panel 2221 Fundamentals Pre-operation InspectionPRE-OPERATION Inspection Pre-operation Inspection Check the Engine Oil Level Maintenance Observe and Obey Deutz F4L 913 Engine Engine oil viscosity requirements Check the Hydraulic Oil LevelCheck the Engine Coolant Level Liquid Cooled Models Scheduled MaintenanceCheck the Batteries At the Ground Controls Function TestsTest Emergency Stop Test the Machine FunctionsTest the Operating Envelope Test Auxiliary ControlsTest the Tilt Sensor At the Platform Controls Test the Steering models with 2 wheel steer Test the Steering models with 4 wheel steerTest the Oscillate Axle Oscillating axle-equipped models Test the Drive Enable SystemTest Drive and Braking Test Limited Drive Speed Workplace Inspection Workplace InspectionStarting the Engine Operating InstructionsEmergency Stop Only use the machine as it was intendedOperation from Platform Auxiliary ControlsOperation from Ground Engine Idle Select rpm Drive EnableTo Drive Regulated Generator if equippedCheck Engine Light Operating Envelope Indicator LightsStopping the Engine After Each UseDecal Inspection DecalsDecals Transport and Lifting Instructions Free-wheel Configuration for WinchingSecuring the Platform Securing to Truck or Trailer for TransitSecuring the Chassis Turntable Chassis Lifting Point Points Lifting Instructions80/60 Specifications80/60 Range of Motion +34