Before You Install Stratagy in Strata CTX...
please read and complete both sides of this checklist.
This checklist only highlights important installation information. Please reference the Stratagy IVP8 or Stratagy DK Installation Guide for details on programming individual features, etc. Unless otherwise noted in these instructions, references to Stratagy apply to both the Stratagy DK (Release 3.3) and Stratagy IVP8 products.
CAUTION! After making any significant program changes to the Stratagy, it is recommended the system be properly shut down and restarted. This copies the most current database to the C:\Stratagy\Archive\Good directory for use by the Automatic System Recovery feature (see “Automatic System Recovery” on page 42 in the Stratagy IVP8 or Stratagy DK Installation Guide). Failure to do so could result in the loss of customer information if the system loses power before it is properly shutdown and rebooted.
1 $UH\RXDZDUHRIWKHSUHVFULEHGKDQGOLQJSUHFDXWLRQVIRUWKH6WUDWDJ\"
Whenever handling Stratagy, always wear the
❐Always hold the unit by its edges. Remember that an electrostatic charge from your body, even your own body oils can damage the Stratagy.
❐Never drop or jar the Stratagy! Care should be taken whenever handling the unit.
❐Temperature changes greater than 20°F cause condensation on Stratagy’s hard drive. If there is such a temperature variation, wait 24 hours before installation.
❐Always keep the Stratagy in its individual shipping box until it’s time to install it in the Strata CTX.
❐Never transport the Stratagy inside the Strata CTX.
2 'R\RXKDYHHYHU\WKLQJ\RXQHHGIRUSURJUDPPLQJ6WUDWDJ\XVLQJ6WUDWDJ\ $GPLQ"
Stratagy Admin Release 3 software is only supported with the Stratagy Flash, Stratagy DK Release 3 and Stratagy IVP8. Use with any Release 2 Stratagy system may cause erratic behavior.
❐Local Administration? You’ll need a PC, 5MB hard drive space, 3.5” 1.44 floppy drive, and 580KB free RAM. You’ll also need a
❐Remote (modem) Administration? Use Stratagy Admin software with Stratagy’s internal (soft)
...or use Toshiba’s 9600 baud
3 ,VWKH6WUDWD&7;UHDG\"
Stratagy is compatible with all Strata CTXs. Strata CTX needs to recognize Stratagy’s DTMF signaling. An ARCS card must be installed in the Strata CTX100 for this DTMF signaling. Strata CTX670 allows four DTMF circuits in its default configuration.
❐Install and program an ARCS card in the Strata CTX100. When installed, the ARCS card by default allows four circuits. Additional licenses may be required, depending upon the Strata CTX configuration and applications.
❐Program slot in Strata CTX before installing the Stratagy. Refer to Strata CTX Programming Manual for details.
Copyright © Toshiba America Information Systems, Inc. | December 2001 |