Step 4: Install Stratagy IVP8
Table 1 Stratagy IVP8 Slot Assignments
DK424i/DK424
Note For the DSS/BLF feature, the Stratagy IVP8 must reside in a
Install the card in a universal slot starting with slot 12 (if a PDKU or PEKU is in slot 11) or slot 13 (if a RSIU is in slot 11).
Important! Do not install the Stratagy IVP8 in slots 27, 28, 31, 37, 38, 47, 48, 51, 57, 58, 67, 68, 71, 77, or 78.
To enable
DK280
Important! The Stratagy IVP8 does not function when installed in slots 31 or 51.
Note For the DSS/BLF feature, the Stratagy IVP8 must reside in a
DK280 (R2) — install the card in any universal slot (except slots 31 and 51), starting with slot 12 of the Base Cabinet.
DK280 (R3 or higher) — install the card in any universal slot (except slots 31 and 51), starting with slot 12 (if a PDKU or PEKU is in slot 11) or slot 13 (if a RSIU is in slot 11).
DK280 (All releases) — To enable
DK40i/DK40/DK16e/DK16
Install the Stratagy IVP8 in any slot in the Expansion KSU where an
Important! Do not install Stratagy IVP8 in slot 18 of the DK40i/DK40/DK16e.
DK40i/DK40/DK16e/DK16: A K5RCU, K5RCU2, or K4RCU3 must be installed in the Base KSU to enable
Note Putting a Stratagy IVP8 into a Strata DK40i/DK40/DK16e/DK16, eliminates eight telephone lines.
DK24, DK56, DK96
Install the card in any slot after slot 01. A CRCU must be installed to enable
DSS/Busy Lamp Feature (For all Strata DK systems)
For the DSS/Busy Lamp feature to operate, the Stratagy IVP8 must monitor the DSS/BLF data from a specific PDKU card. The Strata DK telephone system restricts this capability to certain configurations. The Stratagy IVP8:
•
•
•
Cannot be installed in the first slot of any cabinet (i.e., 11~71).
Can only monitor a PDKU that resides in an
Must always be in a
When Stratagy IVP8 is installed in an