Ericsson BusinessPhone manual RQQHFWLQJ0XOWLSOH8QLWV, Address Selection

Page 42

,QVWDOOLQJ￿D￿'LVSOD\￿8QLW

&RQQHFWLQJ￿0XOWLSOH￿8QLWV

When more than one unit is being used the connections must be repeated in mul- ti drop mode i.e. receive of all Display Units in the system is connected to the transmit of the computer and the ground is common to all devices.

The Serial In (White) wire is not needed in most applications.

Terminal Box

Terminal Box

Red - Serial Out

Black - Ground

PC Serial Port

Connector

Display Unit

Display Unit

Address Selection

Each Display Unit includes a network communication Eprom and address switch module. This module plugs into the keyboard connector socket adjacent to the power connector and enables you to set an address for the associated unit. When the Display Unit is powered up, it reads the network address from the switch module.

4

5

6

4

5

6

 

 

 

 

 

 

 

 

 

 

3

 

7

3

 

7

 

 

 

 

 

 

 

 

 

 

2

 

8

2

 

8

 

 

 

 

 

 

 

 

 

 

1

0

9

1

0

9

 

Power

 

 

 

 

 

Connector

 

 

 

 

 

 

Most significant

Least significant

 

 

 

address bit

address bit

 

 

 

Addresses are set by setting the required values on the two rotary switches of the address module. An address can be any value between 01 and 99 and each display in the network should have a different address number.

The maximum number of displays that can be connected to a single PC Serial Port will depend on the type of display and baud rate used to transfer informa- tion.

BusinessPhone Call Centre Supervisor - Standard

 

Installation Guide

42

EN/LZT BS 102 063/S R2B

Image 42
Contents S i n e s sphone EN/LZTBS 102 063/S R2C HOFRPHWRWKH%XVLQHVV3KRQH &DOO&HQWUH6XSHUYLVRU HOFRPHWRWKH%XVLQHVV3KRQH&DOO&HQWUH6XSHUYLVRU 7DEOHRI&RQWHQWV DQJXDJH8SGDWH QVWDOODWLRQ$SSHQGL 7DEOHRI&RQWHQWV Qwurgxfwlrq KDWVQHZLQ5HOHDVHInstall Acrobat Reader Install CCS software 520HOLYHUHGZLWK&&63DFNDJHCCS Documentation Installation of CCS Documenation Dimensioning Tool for ACDStandard PC Specification for Using Documentation on CD-ROM Fkdqjh 5HTXLUHPHQWV Standard PC SpecificationDVLF+DUGZDUH5HTXLUHPHQWV Rpsxwhu 5HTXLUHPHQWVPC side Number of AgentsExchange to PC Connection Exchange sideApplication Software DVLF6RIWZDUH5HTXLUHPHQWVOperating System Software Registration$GDSWDWLRQ8QLW QVWDOODWLRQ3URFHGXUHV6HULDO3RUWV \VWHP3ULQWHU$SSOLFDWLRQ6RIWZDUH,QVWDOODWLRQ RUODQGDWDEDVHQJLQH%$SSOLFDWLRQ6RIWZDUH,QVWDOODWLRQ Installation Guide Click on install software Click on install ccs standard XVLQHVV3KRQH&DOO&HQWUH6XSHUYLVRUBusinessPhone Call Centre Supervisor Standard $SSOLFDWLRQ6RIWZDUH,QVWDOODWLRQ 1HZ,QVWDOODWLRQ 8SJUDGHDWDEDVHIURP&&69WR&&69 Start the Converting Program$SSOLFDWLRQ6RIWZDUH,QVWDOODWLRQ If you chose the defaults Restart the SystemIf you have not chosen the default directories then 3RVW,QVWDOODWLRQ&RQILJXUDWLRQ DWDEDVH&RQILJXUDWLRQ6HWWLQJ$OLDVHV Click the Aliases tab to open the Aliases TA\CONFIG 3DUDGRULYHUQLWLDO6WDUW8S 6WDUW8S*URXSWindows for Workgroups Time / Date Format0LQLPXP&RQILJXUDWLRQ QLWLDO&KHFNV6WDUW8S No other User exists in the CCS at this timeDQJXDJH8SGDWH QVWDOOLQJ/DQJXDJHLOHVDQJXDJH8SGDWH Hqhudo LVSOD\8QLW&RQQHFWLRQUrdgfdvwxqfwlrq LVSOD\8QLWULYHUV 6WDQGDUG,QIRUPDWLRQLVSOD\8QLWV2WKHULVSOD\8QLWV Design QVWDOOLQJDLVSOD\8QLW 6HULDO&RQQHFWLRQWay D Type Connector QVWDOOLQJDLVSOD\8QLWRQQHFWLQJ0XOWLSOH8QLWV Address SelectionLVSOD\8QLW&RQQHFWLRQ 0DQDJHPHQWXQFWLRQV $GGLQJD1HZLVSOD\8QLW LVSOD\8QLW1DPHLVSOD\8QLW7\SH RpphylfhDXG5DWH $GGUHVVKDQJLQJ&RQQHFWLRQ3DUDPHWHUV 7HVWLQJ&RQQHFWLRQV HOHWLQJD&RQQHFWLRQ6LQJOH&RORXU,QIRUPDWLRQLVSOD\ 7HFKQLFDOGDWD0XOWLFRORXU,QIRUPDWLRQLVSOD\ 7HFKQLFDOGDWDRandom $GGLQJD1HZLVSOD\8QLW 7URXEOH6KRRWLQJ7LSV 99LUWXDOHYLFHULYHU6HWWLQJVHIDXOW3ULQWHUDQG5HSRUWV LVSOD\8QLWV0LVVLQJ$&4XHXHVRU$JHQW*URXSV DWDEDVH3UREOHPV1RDWDLQ5HSRUWV URQJ6FKHGXOHG$FWLRQVQVWDOODWLRQ$SSHQGL RQQHFWLRQEHWZHHQ3&DQGFKDQJHRQQHFWLRQEHWZHHQ3&DQGLVSOD\8QLW XVLQHVV3KRQHHFKDQJHQVWDOODWLRQ$SSHQGL ASBQVWDOODWLRQ$SSHQGL Communication is our business