Vizio EXES-6000 CP-64 operating instructions Programmable Restricted Access for Stations

Page 54

Programmable Restricted Access for Stations

Stations which can use the 6 groups of following functions must be programmed, so as to restrict access to those func- tions by those stations not programmed.

1.All-call paging

2.Conference

Station number

3.General purpose control

Mode 1 (One-shot make output)

00-49

000 ~ 499

4.General purpose control Mode 2 (Make/break output)

00~99 000 ~ 511

00~99

000~511

5.General purpose control

Mode 3 (8 selectable one-shot make output)

1~91~8

Unit No. Condition No.

General purpose control

Mode 4 (8 selectable output or decimal output)

01~64

1 ~ 8, 0 (clear)

(01 ~ 99)

( 0 ~ 9 )

Unit No.

Condition No.

6. General purpose control

Mode 5 (4 decimal digits output)

1 ~ 9 0000 ~ 9999

(Unit No.)

(4-digits)

1.For a conference call, only those stations allowed to use the conference link can dial.

The other members of the conference need not be allowed conference access.

2.No. 200 programming of the specified station must be made in the exchange. For further details, please refer to Installation Hand Book for EXES-6000 CP unit.

– 51 –

Image 54
Contents Functionsand Operating Instructions Contents Privacy Highest Executive PriorityDescription of Each Function Automatic Line Release Programmable Station NumberingTherefore, read the page marked if your system Basic functions, their operating Station StationsHF-600MDesk Hands-Free/Handset Master Station Station Stainless steel panelSpeech functions ToneWhile the continuous calling tone is sent, you can Station operationStart conversation after the calling tone stops Hang up the handset to terminate the conversationPV Type Model HF-620M/630M/631M/650MHands-free Master Station Model HF-620M/630M/631M/650M PV Type Hands-free Substation Model HF-620S/630S/631S/640SPosition Loud speaker Loud speaker Handset Speaker Speaker volume switch Hands-free / Handset Substation Model HF-600S/610 Sound volume of the loud speaker may be adjusted Hands-free / Handset substation Model HF-600S/610SPosi Functions EXES-6000 CP-64 PTTFunctions EXES-6000 CP-64 Chapter Part names and functions of the station keyboard Paging response may be made either by pressing Function descriptionBesides fixed standard functions, there are selectable Standard FunctionsPersons Pager Calling and ResponseOptional Functions 1000 ~ 01~31 Unit No. Condition No Unit No -digitsPrivacy Automatic Line ReleaseCamp-On-Busy When, in dialing, all of the numbers are not dialed withinCamp-On Privacy Press-To-TalkMic Off Press-To-Talk Control Single Digit Dialing Single digit registrationAutomatic Access To Paging Master Sub RelationshipLine is connected with master station Personal 4-digit number which may be programmed to Personal Number CallThose who are frequently away from their assigned station Is increased to 2 orContinuous Calling Tone Is depressed by this partyComparison of continuous calling tones Cancel Is the Remote reponse program Remote ResponseProgramming the remote response group Example Call Transfer Paging during Normal Calls Group HuntingSecretary Transfer Digit the executive stationSecretary Transfer and Call Transfer Secretary Transfer end Cell Transfer PrivacyWhen you will be away from your station and wish all Cancellation of Call ForwardingCall Forwarding His station Executive PriorityResume Placing the priority call dialsWhen the called station is busy or in the Conference mode Highest Executive PriorityFunction is cancelled and the normal mode is restored ConferenceAt any station PagingTouch dialing External PA paging and Station pagingPaging response Combination zone No 90 ~ Other Paging ModesCombination paging ExampleHow to select the paging area and make the paging call All-call paging depending on the call rangeAll zones are paged at the same time by all-call paging Zone No ~ 9 01 ~Combination Paging All call pagingcombination paging= individual zone pagingExample To operate combination paging. No registration indi Emergency All-Call Paging Emergency all-call station, NoDialing method For dial operation Paging PriorityZones 01-31, all-call 00, or MadePersonal Number Paging This function allows those who are frequently away fromProgrammable Station Numbering Are usedThis function allows the system to have Programmable Group Blocking Example of Paging responseProgrammable Restricted Access for Stations Time-Out of Paging Call Selectable Calling ToneSelectable Paging Pre-Announcement Tone Duration Time-Out of ConversationIn/Out Annunciation Destination Annunciation Indication From any station, the call is put through to the stationPersonal number call Station Memory function. Adopting this function Is heard. Press after cancelling the dial toneCalling Party Indication Lamp Type Lamp goes out after the conversation is canelledTo cancel a waiting station number without calling, dial Calling Party Indication Numerical TypePocket Pager General Purpose Control One contact out of 8 selectable make outputs is4 decimal digits are indicated Clear entry Simplified PagingClear Entry and Conversation Over Conversation over768 stations Tie-line Tie-line Connections of Exchanges Purpose of tie-line connectionNumber of stations, paging zones and links Numbering schedule for stations and paging zones Camp-on-Busy Restricted AccessAutomatic Access to Paging Press-to-TalkPaging through PA System and response Calls can be transferred to a third party after pagCall can only be made from the stations No ~ Restrictions Resulting from Tie-line Connection Group BlockingEXES-6000, CP-64 Summary of Dial Operations 1000 ~000 ~ 00~49 00~99 Camp-On-Busy PrivacyEmployed when a person in a high noise level area is called DepressInvolved pick up a handset Single digit registration Register in advance as follows Tie-line Single digits of station numberSame manner as other single digit dialing, and results FunctionPersonal Number Call Continuous calling tone Touch dialing at each Substation Cancells the Remote reponse programEach of Substation within the group registers Remote response group within the stations connectParty called touch dials Original call is then held and the holding tone is transAsked whether he will accept the call. If he agrees to Key Or the third party replaces a handsetGrammed from the beginning Secretary Transfer Secretary/Executive association within a groupAt her station. This sets the privacy tone sounding continu PrivacySecretary Transfer and Call Transfer Tie-line NP TypeHighest Executive Priority Hands-Free conference call can be made with up to Possible for any of the 4 participants to call up anyPerson wishing to drop out of the conference should dial Zone No To respond to a zone paging, depress Variety of paging modes allows paging over a wide areaPaging. The same paging zones Exchange a No ~ At any station and the paged party is put through to995 Registration of the stations consecutive station numbers All-Call Paging and Individual Zone PagingAll-call paging response Zone No ~Selectable First Station Number of Each Exchange Programmable station number series for each exchange Function C Example of Group Blocking registration Programmable Restricted Access for Stations ConferenceSecond single note tone or 0.3 second warble tone From any station, the personal number is cancelled Registered with the personal numberIs turned off Causes the calling partys lamp on the indication panel to Group may have the calling party indication panels whichIt is also possible to equip the system with the Calling Is heard. PressTie-line Is dialed by the party called from the nearest master Selectable output type indication panel Condition No Unit No Tie-line External speaker Connected to the line for station KOBE,JAPAN