3-6 The order of Tie-line link usage

The Tie-line Link Number which is used in calls between exchanges is not directly indicated, but you can possibly get it from the link number which is indicated on the HC-62.

When one Tie-line Link brings up some problems which cause the system not to work properly, try to find which link number is causing the problems from the indication on the HC-62 of the exchange making the call.

As Fig. 1 and Fig. 2 show, in the exchanges which make calls, the DL Link Number corresponds with Tl Tie-line Link Number.

In the exchange which is called, the Tie-line Link Number of the Tl Unit is fixed by connection between exchanges.

DL Links are used in numerical order.

1. Tie-line for 2 exchanges

Exchange which calls

Exchange which is called

Station which is called

Station which calls

Connection Cable between exchanges

Fig. 1

2. Tie-line for 3 exchanges

Exchange which is called

 

Exchange which calls

No.47O

Station which is called

Station which calls

Fig. 2

— 14 —

Image 15
Contents CP-63 Contents Required Installation Hand Book Systems Introduction to the Installation Manual for EXES-6000Installation Hand Book of EXES-6000 Installation Hand Book of ExchangeFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack Function of the Central Processing Unit CP-63 TIE-LINE Connection of the ExchangesBlock diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange Function Select Switches SW-E SW-C SW-BFixed MINI-JUMPER JP2 Initial CP-63 SET UP Check of ROM & NMOS-RAM No calls on the system Trouble ShootingTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link SW-A SW-B SW-C SW-D CP-63 DIP Switches for Function SelectionON/OFF Clearance at one time Function Code Table for Station no ProgrammingOFF Programming of SystemOperating for Programming Programming of each FunctionStation no Programming for Each Function Executive Priority Function Code 50 Highest PriorityYES Continuous Calling Tone Step Continuous Calling Tone Function CodeStations Allowed Access to ALL Call Step Stations Allowed Access to ALL Call Function CodeStations Allowed Access to Conference Step Stations Allowed Access to Conference Function CodeHandset Substations Allowed Access to Paging Step Automatic Access to Paging Function CodeCall by Dialing Picking up the Handset Complementary NotesStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Step Stations Allowed Access to MAKE/BREAK Output Function CodeTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship MASTER/SUB Relationship Function CodeGroup Hunting Function Code Establishment of Each Paging Zone Paging Zone Function CodeEstablishment of Each Group Group BlockingRegistration of station numbers having indication panel Calling Party Indication Lamp Type Function CodeAllowing Calls Among Groups Group Blocking 2 Allowing Calls Among Groups Function CodeAllowing Access to Paging Zones Programmable Station Numbering Function Code Programming of Single Station NumberProgrammable Station Numbering Restriction of programmable station numbering Programming of Serial Station NumbersClearance of Each Function at a Time Programming Data TableInitial Programming Initial Programming of the ExchangeFunction Function Table for the SystemFunction Table for Stations Programming DataProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Channel Select Cable YR-802 or YR-806DIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Application Explanation of Data Transmitting Unit Output ChannelsChannel Selection Functions DescriptionChannel 0 CH In/Out Annunciation Explanation of Data Receiving Unit Output DataChannel Select Switch Channel 2 CH Calling Party Indication Lamp Type Channel Select SwitchChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan