FUNCTIONS WHICH REQUIRE ADDITIONAL UNITS

Those functions of the CP-63 which require either the addition of specific units or processing in existing units are as mentioned below. Before installation and adjustment of equipment, make sure to check your system.

(For Data Transmitting and Receiving units, refer to Part 2. "Function Selection for Data Transmitting and Receiving units" Page 49.)

Function

Additional Equipment

Unit Model

Required

Number

 

Talk- Back from

Talk-Back Unit

TK-12

paging speaker

 

 

Conference

Conference Unit

CL-62

Remarks

Not yet available for sale.

Build this unit in all exchanges connected by tie-line. It is not possible to originate a conference from a station connected to the exchange without the CL unit but possible to participate in the conference from that station.

External PA Paging

Paging Interface Unit

PI-62

Station Paging

Paging Interface Unit

PI-62

 

Data Transmitting Unit

DT-E11

Indication and

 

 

Control

 

 

 

Data Receiving Unit

DR-B61

Tie-line System

Tie-line Interface Unit

TI-62

External PA Equipment is required.

1.Wiring of "Station Paging Assignment" located at the back of the frame of the Exchange.

2.Cutting of LM-62 jumper wire to split station paging system.

The number that can be mounted on the cabinet-mount type exchange is one (1). Use the connection cable YR-806.

When more than 2 pieces are mounted, we suggest you use rack-mount type exchange. For connection between

the exchange and the DT-E11, use the YR-802, and

the YR-803 for extension of the DT-E11 .

Such devices as indicator, control unit etc. can be made by using this unit and 24V DC power supply.

Insert this unit into a slot intended for the PI unit No. 2 (Zone No. 8-15).

— 3 —

Image 4
Contents CP-63 Contents Introduction to the Installation Manual for EXES-6000 Installation Hand Book of EXES-6000Installation Hand Book of Exchange Required Installation Hand Book SystemsFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack TIE-LINE Connection of the Exchanges Function of the Central Processing Unit CP-63Block diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange SW-C SW-B Function Select Switches SW-EFixed MINI-JUMPER JP2 Initial CP-63 SET UP Trouble Shooting Check of ROM & NMOS-RAM No calls on the systemTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link CP-63 DIP Switches for Function Selection SW-A SW-B SW-C SW-DON/OFF Function Code Table for Station no Programming Clearance at one timeProgramming of System OFFProgramming of each Function Operating for ProgrammingExecutive Priority Function Code 50 Highest Priority Station no Programming for Each FunctionYES Continuous Calling Tone Function Code Continuous Calling Tone StepStations Allowed Access to ALL Call Function Code Stations Allowed Access to ALL Call StepStations Allowed Access to Conference Function Code Stations Allowed Access to Conference StepAutomatic Access to Paging Function Code Handset Substations Allowed Access to Paging StepComplementary Notes Call by Dialing Picking up the HandsetStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Function Code Stations Allowed Access to MAKE/BREAK Output StepTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship Function Code MASTER/SUB RelationshipGroup Hunting Function Code Paging Zone Function Code Establishment of Each Paging ZoneGroup Blocking Establishment of Each GroupCalling Party Indication Lamp Type Function Code Registration of station numbers having indication panelGroup Blocking 2 Allowing Calls Among Groups Function Code Allowing Calls Among GroupsAllowing Access to Paging Zones Programming of Single Station Number Programmable Station Numbering Function CodeProgrammable Station Numbering Programming of Serial Station Numbers Restriction of programmable station numberingProgramming Data Table Initial ProgrammingInitial Programming of the Exchange Clearance of Each Function at a TimeFunction Table for the System FunctionProgramming Data Function Table for StationsProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Cable YR-802 or YR-806 Channel SelectDIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Explanation of Data Transmitting Unit Output Channels Channel Selection FunctionsDescription ApplicationExplanation of Data Receiving Unit Output Data Channel 0 CH In/Out AnnunciationChannel Select Switch Channel Select Switch Channel 2 CH Calling Party Indication Lamp TypeChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan