TOA Electronics CP-63 manual Cable YR-802 or YR-806, Channel Select

Page 50

PART 2. FUNCTION SELECTION FOR DATA

TRANSMITTING AND RECEIVING UNITS

9.SETTING OF CHANNEL SELECT SWITCH OF TRANSMITTING UNIT (DT-E11) AND WORD SELECT SWITCH OF RECEIVING UNIT (DR-B61)

NOTE

1.Connect the DT-E11 and DR-B61 to Exchange correctly. (Refer to operation manuals of DT-E11 and DR-B61).

2.Set the function select switches (DIP SWITCH) on CP-63 cor- rectly and be sure to enter initial programming and function registration at programming station No.200.

3.Remove the front panel of Data Transmitting Unit (DT-E11) and take out the printed circuit board. Then set the channel select switches located on the printed circuit board, according to the

Connecting

Cable YR-802 or YR-806

One Pair Cable

To other DR-B61

Connecting

Cable YR-803

To other

DT-E11

To other RD-B61

CHANNEL SELECT

Switch (SW-1)

necessary functions such as IN/OUT Annunciation, Calling Party Indication etc,and replace in the Unit.

(Refer to 13. Explanation of Data Transmitting Unit Output Data, Page 53).

4.The DT-E11 sends out 512 bit data (16 bit x 32 words) to control relays on Data Receiving Unit (DR-B61). Therefore set the two word select switches on DR-B61, according to necessary output mode. SW-1 is for Relay No.1 to No.16 and SW-2 is for Relay No.17 to No.32. See Page 51 for details.

(Refer to Explanation of Date Receiving Unit Output Channels.)

5.Connecting Cable YR-802 is used for the Rack mounting system. Connecting Cable YR-806 is used for the Standard Cabinet mounting system with only One (1) DT-E11 unit.

WORD SELECT Switch (SW-1, SW-2)

— 49 —

Image 50
Contents CP-63 Contents Installation Hand Book of Exchange Introduction to the Installation Manual for EXES-6000Installation Hand Book of EXES-6000 Required Installation Hand Book SystemsFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack TIE-LINE Connection of the Exchanges Function of the Central Processing Unit CP-63Block diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange Fixed MINI-JUMPER JP2 Function Select Switches SW-ESW-C SW-B Initial CP-63 SET UP Trouble Shooting Check of ROM & NMOS-RAM No calls on the systemTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link CP-63 DIP Switches for Function Selection SW-A SW-B SW-C SW-DON/OFF Function Code Table for Station no Programming Clearance at one timeProgramming of System OFFProgramming of each Function Operating for ProgrammingYES Station no Programming for Each FunctionExecutive Priority Function Code 50 Highest Priority Continuous Calling Tone Function Code Continuous Calling Tone StepStations Allowed Access to ALL Call Function Code Stations Allowed Access to ALL Call StepStations Allowed Access to Conference Function Code Stations Allowed Access to Conference StepAutomatic Access to Paging Function Code Handset Substations Allowed Access to Paging StepComplementary Notes Call by Dialing Picking up the HandsetStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Function Code Stations Allowed Access to MAKE/BREAK Output StepTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship Function Code MASTER/SUB RelationshipGroup Hunting Function Code Paging Zone Function Code Establishment of Each Paging ZoneGroup Blocking Establishment of Each GroupCalling Party Indication Lamp Type Function Code Registration of station numbers having indication panelGroup Blocking 2 Allowing Calls Among Groups Function Code Allowing Calls Among GroupsAllowing Access to Paging Zones Programmable Station Numbering Programmable Station Numbering Function CodeProgramming of Single Station Number Programming of Serial Station Numbers Restriction of programmable station numberingInitial Programming of the Exchange Programming Data TableInitial Programming Clearance of Each Function at a TimeFunction Table for the System FunctionProgramming Data Function Table for StationsProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Cable YR-802 or YR-806 Channel SelectDIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Description Explanation of Data Transmitting Unit Output ChannelsChannel Selection Functions ApplicationExplanation of Data Receiving Unit Output Data Channel 0 CH In/Out AnnunciationChannel Select Switch Channel Select Switch Channel 2 CH Calling Party Indication Lamp TypeChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan