TOA Electronics CP-63 manual Introduction to the Installation Manual for EXES-6000

Page 3

INTRODUCTION TO THE INSTALLATION MANUAL FOR EXES-6000

This manual forms part of the Installation Manual for TOA INTER- COM SYSTEM EXES-6000.

You may add the CP-63 to your TOA INTERCOM SYSTEM EXES- 6000, according to your specific needs, to obtain various other functions. Correct operation of these additional functions is not performed by simply connecting the additional equipments/devices. Provision of such additional function requires the following:

(1)Connection of the additional equipment, as required.

(2)Selection of functions which satisfy your needs and setting up these functions in the respective equipment.

For (1) Connections of Equipment, etc., refer to "

Installation

Handbook of Model EX-610/620 EXCHANGE" or

Operation

Manual of Data Transmitting and Receiving Units", etc.

 

This "Installation Handbook of CP-63" deals principally with (2) Selection of functions and setting up of respective equipment.

This Handbook also explains the connection method for the EXES- 6000 Tie-line System using the CP-63 and the TI-62 units.

There are certain minimum installation requirements to be met even through you may not need many additional functions or additonal equipment, it is still necessary to read "2. Initial CP-63 Set Up (Page 12)". When you may use only some of the additional func- tions or equipments, it is not necessary to read instructions on unrequired functions. Make sure, however, that careful study of the necessary parts of this booklet should be done before proceeding further.

INSTALLATION HAND BOOK OF EXES-6000

EXES-6000

EX-610/620

INSTALLATION HAND BOOK OF EXCHANGE 133-21-100-9

EXES-6000 CP-63

INSTALLATION HAND BOOK 133-21-081-1 (This Hand Book)

EXES-6000 CP-63

INITIAL CHECKING SHEET FOR THE SYSTEM 133-21-085-5

DATA TRANSMITTING AND RECEIVING UNIT "DT-E11 OPERATION MANUAL" 133-05-094-1A "DR-B61 OPERATION MANUAL" 133-05-095-0

Manuals Necessary for Installation of Exchange

REQUIRED INSTALLATION HAND BOOK

SYSTEMS OF

EXES-6000

Normal Conversation and Paging System

Normal Conversation and Paging System with Display and Control Functions

Tie-line System with Normal Conversation and Paging Functions

Tie-line System with Normal Conversation, Paging, Display

and Control Functions

EX-610/620

CP-62

CP-62

CP-63

CP-63

DATA TRANSMITTING

INSTALLATION

INSTALLATION

INITIAL

INSTALLATION

INITIAL

AND RECEIVING UNIT

HAND BOOK

HAND BOOK

CHECKING

HAND BOOK

CHECKING

OPERATION MANUAL

OF EXCHANGE

 

SHEET

 

SHEET

 

— 2 —

Image 3
Contents CP-63 Contents Required Installation Hand Book Systems Introduction to the Installation Manual for EXES-6000Installation Hand Book of EXES-6000 Installation Hand Book of ExchangeFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack Function of the Central Processing Unit CP-63 TIE-LINE Connection of the ExchangesBlock diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange Function Select Switches SW-E SW-C SW-BFixed MINI-JUMPER JP2 Initial CP-63 SET UP Check of ROM & NMOS-RAM No calls on the system Trouble ShootingTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link SW-A SW-B SW-C SW-D CP-63 DIP Switches for Function SelectionON/OFF Clearance at one time Function Code Table for Station no ProgrammingOFF Programming of SystemOperating for Programming Programming of each FunctionStation no Programming for Each Function Executive Priority Function Code 50 Highest PriorityYES Continuous Calling Tone Step Continuous Calling Tone Function CodeStations Allowed Access to ALL Call Step Stations Allowed Access to ALL Call Function CodeStations Allowed Access to Conference Step Stations Allowed Access to Conference Function CodeHandset Substations Allowed Access to Paging Step Automatic Access to Paging Function CodeCall by Dialing Picking up the Handset Complementary NotesStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Step Stations Allowed Access to MAKE/BREAK Output Function CodeTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship MASTER/SUB Relationship Function CodeGroup Hunting Function Code Establishment of Each Paging Zone Paging Zone Function CodeEstablishment of Each Group Group BlockingRegistration of station numbers having indication panel Calling Party Indication Lamp Type Function CodeAllowing Calls Among Groups Group Blocking 2 Allowing Calls Among Groups Function CodeAllowing Access to Paging Zones Programmable Station Numbering Function Code Programming of Single Station NumberProgrammable Station Numbering Restriction of programmable station numbering Programming of Serial Station NumbersClearance of Each Function at a Time Programming Data TableInitial Programming Initial Programming of the ExchangeFunction Function Table for the SystemFunction Table for Stations Programming DataProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Channel Select Cable YR-802 or YR-806DIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Application Explanation of Data Transmitting Unit Output ChannelsChannel Selection Functions DescriptionChannel 0 CH In/Out Annunciation Explanation of Data Receiving Unit Output DataChannel Select Switch Channel 2 CH Calling Party Indication Lamp Type Channel Select SwitchChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan