TOA Electronics CP-63 manual Example of Exchange Mounted on Intercom Cabinet Rack

Page 5

Example of Exchange Mounted on Intercom Cabinet Rack

(For Tie-line System Including All-Call Paging and 7 Individual Zone Paging unit and one Data Transmitting unit)

Exchange EX-620 (for 128 stations)

Exchange EX-610 (for 64 stations)

Central Processing Unit CP-63

Output Control Unit OC-62

Highway Control Unit HC-62

Signal Generating and Distributing Unit SG-62

Conference Link Unit CL-62 (In this location, DL-62 is also mountable.)

Duplex Link Unit DL-62

Line Modem Unit LM-62

Paging Interface Unit PI-62 (In this location, LM-62 is also mountable.) (Zone 0-7 with All-Call Paging)

Tie-line Interface Unit TI-62

Perforated Panel PF-022G *

Data Transmitting Unit DT-E11 (In the standard system, Perforated Panel PF-012G should come in this position.)*

Junction Cable YR-806 (Cable length: 1000mm) (YR-802 (Cable

length: 400mm) is not available.)

Note.*

The Exchange Cabinet Rack CR-610 or CR-620 includes Perforated Panels PF-012G and PF-022G.

Power Supply Unit DS-620

Power Switch

AC Fuse

DC Fuse

Battery Fuse

Exchange Cabinet Rack CR-620

Exchange Frame FR-620

Power Supply Unit DS-610

Power Indication Lamp

Battery Power Indication Lamp

Buzzer Stop Switch

Exchange Cabinet Rack CR-610

Exchange Frame FR-610

— 4 —

Image 5
Contents CP-63 Contents Installation Hand Book of EXES-6000 Introduction to the Installation Manual for EXES-6000Installation Hand Book of Exchange Required Installation Hand Book SystemsFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack Function of the Central Processing Unit CP-63 TIE-LINE Connection of the ExchangesBlock diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange Fixed MINI-JUMPER JP2 Function Select Switches SW-ESW-C SW-B Initial CP-63 SET UP Check of ROM & NMOS-RAM No calls on the system Trouble ShootingTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link SW-A SW-B SW-C SW-D CP-63 DIP Switches for Function SelectionON/OFF Clearance at one time Function Code Table for Station no ProgrammingOFF Programming of SystemOperating for Programming Programming of each FunctionYES Station no Programming for Each FunctionExecutive Priority Function Code 50 Highest Priority Continuous Calling Tone Step Continuous Calling Tone Function CodeStations Allowed Access to ALL Call Step Stations Allowed Access to ALL Call Function CodeStations Allowed Access to Conference Step Stations Allowed Access to Conference Function CodeHandset Substations Allowed Access to Paging Step Automatic Access to Paging Function CodeCall by Dialing Picking up the Handset Complementary NotesStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Step Stations Allowed Access to MAKE/BREAK Output Function CodeTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship MASTER/SUB Relationship Function CodeGroup Hunting Function Code Establishment of Each Paging Zone Paging Zone Function CodeEstablishment of Each Group Group BlockingRegistration of station numbers having indication panel Calling Party Indication Lamp Type Function CodeAllowing Calls Among Groups Group Blocking 2 Allowing Calls Among Groups Function CodeAllowing Access to Paging Zones Programmable Station Numbering Programmable Station Numbering Function CodeProgramming of Single Station Number Restriction of programmable station numbering Programming of Serial Station NumbersInitial Programming Programming Data TableInitial Programming of the Exchange Clearance of Each Function at a TimeFunction Function Table for the SystemFunction Table for Stations Programming DataProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Channel Select Cable YR-802 or YR-806DIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Channel Selection Functions Explanation of Data Transmitting Unit Output ChannelsDescription ApplicationChannel 0 CH In/Out Annunciation Explanation of Data Receiving Unit Output DataChannel Select Switch Channel 2 CH Calling Party Indication Lamp Type Channel Select SwitchChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan