TOA Electronics CP-63 manual Function Code Table for Station no Programming, Clearance at one time

Page 19

6. FUNCTION CODE TABLE FOR STATION NO. 200 PROGRAMMING

A. Clearance at one time

Function

Function

 

Func-

 

tion

Group

 

 

 

Code

 

 

 

 

Numbering schedules

40

 

of Tie-line system

 

 

 

 

 

Selection of Calling

 

41

 

Tone

 

 

 

 

S

Selection of Paging

 

42

Pre-announcement

Tone

 

 

 

Time-out of

 

45

 

Conversation

 

 

Time-out of Paging

 

46

 

Call

 

 

 

 

 

Executive Priority

 

50

 

Continuous Calling

 

 

Tone

51

 

Station Allowed

52

Access to All Call

 

Stations Allowed

53

Access toConference

 

Automatic Access to

54

Paging

 

AStations Allowed

 

Access to One Shot

56

 

Make Output

 

 

Stations Allowed

 

 

Access to Make/

57

 

Brake Output

 

 

Stations Allowed

 

 

Access to 8 Selectable/

58

 

Decimal Output

 

 

Stations Allowed

 

 

Access to 4 Decimal

59

 

Digits Output

 

 

Secretary Transfer

60

B

Master/Sub

61

 

Group Hunting

62

 

Paging Responce,

70

 

Paging Priority

C

Group Blocking of

71

Each Group

 

Group of Calling

72

 

Party Indication

 

 

 

Group Blocking:

 

 

Allowing Calls

81

D

Among Groups

 

Group Blocking:

 

 

 

 

AllowingAccess

82

 

to Paging Zones

 

E

Programable Station

90

Numbering

 

*

Personal Number

 

Single Digit Dialing

-

RemoteResponse

Clearance of Function

Confirmation tone

Confirmation tone

Confirmation tone

Confirmation tone

Confirmation tone

Confirmation tone

Confirmation tone

Confirmation tone

Confirmation tone

Confirmation tone

Function Registration on All Stations

Confir- mation tone

Clearance of Function by Function Group

Confir-

mation (ClearsfunctiongroupS) tone

Confir-

(Clears function group A)

mation

tone

 

Confir-

 

mation

(Clears function group B)

tone

 

Confir-

 

mation

(Clears function group C)

tone

 

Confir-

 

mation

(Clears function group D)

tone

 

Confir-

 

mation

(Clears function group E)

tone

 

Confir-

(Clears functions of Personal

mation

No., Single Digit Dialing and

tone

Remote Response)

Note: *Can be registered at each station.

— 18 —

Image 19
Contents CP-63 Contents Required Installation Hand Book Systems Introduction to the Installation Manual for EXES-6000Installation Hand Book of EXES-6000 Installation Hand Book of ExchangeFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack Function of the Central Processing Unit CP-63 TIE-LINE Connection of the ExchangesBlock diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange SW-C SW-B Function Select Switches SW-EFixed MINI-JUMPER JP2 Initial CP-63 SET UP Check of ROM & NMOS-RAM No calls on the system Trouble ShootingTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link SW-A SW-B SW-C SW-D CP-63 DIP Switches for Function SelectionON/OFF Clearance at one time Function Code Table for Station no ProgrammingOFF Programming of SystemOperating for Programming Programming of each FunctionExecutive Priority Function Code 50 Highest Priority Station no Programming for Each FunctionYES Continuous Calling Tone Step Continuous Calling Tone Function CodeStations Allowed Access to ALL Call Step Stations Allowed Access to ALL Call Function CodeStations Allowed Access to Conference Step Stations Allowed Access to Conference Function CodeHandset Substations Allowed Access to Paging Step Automatic Access to Paging Function CodeCall by Dialing Picking up the Handset Complementary NotesStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Step Stations Allowed Access to MAKE/BREAK Output Function CodeTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship MASTER/SUB Relationship Function CodeGroup Hunting Function Code Establishment of Each Paging Zone Paging Zone Function CodeEstablishment of Each Group Group BlockingRegistration of station numbers having indication panel Calling Party Indication Lamp Type Function CodeAllowing Calls Among Groups Group Blocking 2 Allowing Calls Among Groups Function CodeAllowing Access to Paging Zones Programming of Single Station Number Programmable Station Numbering Function CodeProgrammable Station Numbering Restriction of programmable station numbering Programming of Serial Station NumbersClearance of Each Function at a Time Programming Data TableInitial Programming Initial Programming of the ExchangeFunction Function Table for the SystemFunction Table for Stations Programming DataProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Channel Select Cable YR-802 or YR-806DIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Application Explanation of Data Transmitting Unit Output ChannelsChannel Selection Functions DescriptionChannel 0 CH In/Out Annunciation Explanation of Data Receiving Unit Output DataChannel Select Switch Channel 2 CH Calling Party Indication Lamp Type Channel Select SwitchChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan