TOA Electronics CP-63 manual Programming of Serial Station Numbers

Page 41

B. Programming of Serial Station Numbers

PROGRAMMABLE STATION NUMBERING

Step 1

Touch

 

 

Function Code

 

 

 

New Registration?

NO

 

 

 

 

 

 

YES

 

 

First

Last

 

First

 

Last

Hardwired Station No. Hardwired Station No. Programmed Station No. Programmed Station No.

First

Last

 

First

 

Last

Hardwired Station No. Hardwired Station No. Programmed Station No. Programmed Station No.

 

 

Confirmation tone

 

 

NO

New Registration finished?

 

 

 

 

 

 

 

YES

 

 

 

 

Release?

NO

 

 

 

 

 

 

 

 

YES

 

 

First

Last

 

First

Last

Hardwired Station No. Hardwired Station No. Hardwired Station No. Hardwired Station No.

First

Last

 

First

Last

Hardwired Station No. Hardwired Station No. Hardwired Station No. Hardwired Station No.

 

 

Confirmation tone

 

 

NO

Release finished?

 

 

 

 

 

 

Return

 

 

NOTES

 

 

 

 

 

1. To release all registered Programmed Station No.'s at one time,

2.

Any one Programmed Station No. cannot be assigned to more

 

(Confirmation tone

 

than one Hardwired Station.

Touch

 

 

 

will be heard.)

 

 

 

10 times

3.

CP DIP switch D-5 must be "ON" to employ this function.

 

 

C. Restriction of programmable station numbering

Each station number can be programmable in the station number series of the exchanges A, B and C that have been determined by the function of the "Selectable First Station Number" (Page 19).

Restriction of station numbers (*1) and (*2)

<Example 1> With personal number(Standard)

<Example 2> Without personal number

<Example 3>

Exchange

Hardwired

Programmed

Exchange

Hardwired

Programmed

Exchange

Station No.

Station No.

Station No.

Station No.

 

 

 

A

200~327

200~469

A

100~227

100~399

A

B

470~597

470~739

B

400~527

400~699

B

C

740~867

740~999

C

700~727

700~999

C

Hardwired Programmed

Station No. Station No.

200~327 200~399

400~527 400~599

600~727 600~799

— 40 —

Image 41
Contents CP-63 Contents Installation Hand Book of EXES-6000 Introduction to the Installation Manual for EXES-6000Installation Hand Book of Exchange Required Installation Hand Book SystemsFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack Function of the Central Processing Unit CP-63 TIE-LINE Connection of the ExchangesBlock diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange Fixed MINI-JUMPER JP2 Function Select Switches SW-ESW-C SW-B Initial CP-63 SET UP Check of ROM & NMOS-RAM No calls on the system Trouble ShootingTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link SW-A SW-B SW-C SW-D CP-63 DIP Switches for Function SelectionON/OFF Clearance at one time Function Code Table for Station no ProgrammingOFF Programming of SystemOperating for Programming Programming of each FunctionYES Station no Programming for Each FunctionExecutive Priority Function Code 50 Highest Priority Continuous Calling Tone Step Continuous Calling Tone Function CodeStations Allowed Access to ALL Call Step Stations Allowed Access to ALL Call Function CodeStations Allowed Access to Conference Step Stations Allowed Access to Conference Function CodeHandset Substations Allowed Access to Paging Step Automatic Access to Paging Function CodeCall by Dialing Picking up the Handset Complementary NotesStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Step Stations Allowed Access to MAKE/BREAK Output Function CodeTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship MASTER/SUB Relationship Function CodeGroup Hunting Function Code Establishment of Each Paging Zone Paging Zone Function CodeEstablishment of Each Group Group BlockingRegistration of station numbers having indication panel Calling Party Indication Lamp Type Function CodeAllowing Calls Among Groups Group Blocking 2 Allowing Calls Among Groups Function CodeAllowing Access to Paging Zones Programmable Station Numbering Programmable Station Numbering Function CodeProgramming of Single Station Number Restriction of programmable station numbering Programming of Serial Station NumbersInitial Programming Programming Data TableInitial Programming of the Exchange Clearance of Each Function at a TimeFunction Function Table for the SystemFunction Table for Stations Programming DataProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Channel Select Cable YR-802 or YR-806DIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Channel Selection Functions Explanation of Data Transmitting Unit Output ChannelsDescription ApplicationChannel 0 CH In/Out Annunciation Explanation of Data Receiving Unit Output DataChannel Select Switch Channel 2 CH Calling Party Indication Lamp Type Channel Select SwitchChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan