8. PROGRAMMING DATA TABLE

INITIAL PROGRAMMING

Note. (Mark *)

The first station of each exchange becomes the Programming Station:

Exchange "A" . . . . . . . . . . . . . . . . . . . . . . . . . No. 200 (100)

Exchange "B" . . . . . . . . . . . . . . . . . . . . . . . . . No. 470 (400)

Exchange "C" . . . . . . . . . . . . . . . . . . . . . . . . . No. 740 (700)

Initial Programming of the Exchange

1.Place program switch on front panel of the CP "ON" Dial operation from station No. 200 (100). *

2.Dial tone will be heard (Station No. 200 (100) becomes a programming station)

3.

Confirmation tone will be heard (Clears function group S)

4.

Confirmation tone will be heard (Clears function group A)

5.

Confirmation tone will be heard (Clears function group B)

6.

Confirmation tone will be heard (Clears function group C)

7.

Confirmation tone will be heard (Clears function group D)

8.

Confirmation tone will be heard (Clears function group E)

9.

Confirmation tone will be heard.

 

(Clears personal numbers, single digit dial numbers and remote numbers)

10.

Program necessary functions.

 

(Refer to separate instructions for each function)

11.Place program switch on front panel of the CP in "OFF" position.

12.

(Station No. 200 (100) becomes a normal station.) *

Clearance of Each Function at a Time

Confirmation tone

Establishment of Function on All Stations at a Time

Confirmation tone

— 41 —

Image 42
Contents CP-63 Contents Installation Hand Book of Exchange Introduction to the Installation Manual for EXES-6000Installation Hand Book of EXES-6000 Required Installation Hand Book SystemsFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack TIE-LINE Connection of the Exchanges Function of the Central Processing Unit CP-63Block diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange Function Select Switches SW-E SW-C SW-BFixed MINI-JUMPER JP2 Initial CP-63 SET UP Trouble Shooting Check of ROM & NMOS-RAM No calls on the systemTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link CP-63 DIP Switches for Function Selection SW-A SW-B SW-C SW-DON/OFF Function Code Table for Station no Programming Clearance at one timeProgramming of System OFFProgramming of each Function Operating for ProgrammingStation no Programming for Each Function Executive Priority Function Code 50 Highest PriorityYES Continuous Calling Tone Function Code Continuous Calling Tone StepStations Allowed Access to ALL Call Function Code Stations Allowed Access to ALL Call StepStations Allowed Access to Conference Function Code Stations Allowed Access to Conference StepAutomatic Access to Paging Function Code Handset Substations Allowed Access to Paging StepComplementary Notes Call by Dialing Picking up the HandsetStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Function Code Stations Allowed Access to MAKE/BREAK Output StepTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship Function Code MASTER/SUB RelationshipGroup Hunting Function Code Paging Zone Function Code Establishment of Each Paging ZoneGroup Blocking Establishment of Each GroupCalling Party Indication Lamp Type Function Code Registration of station numbers having indication panelGroup Blocking 2 Allowing Calls Among Groups Function Code Allowing Calls Among GroupsAllowing Access to Paging Zones Programmable Station Numbering Function Code Programming of Single Station NumberProgrammable Station Numbering Programming of Serial Station Numbers Restriction of programmable station numberingInitial Programming of the Exchange Programming Data TableInitial Programming Clearance of Each Function at a TimeFunction Table for the System FunctionProgramming Data Function Table for StationsProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Cable YR-802 or YR-806 Channel SelectDIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Description Explanation of Data Transmitting Unit Output ChannelsChannel Selection Functions ApplicationExplanation of Data Receiving Unit Output Data Channel 0 CH In/Out AnnunciationChannel Select Switch Channel Select Switch Channel 2 CH Calling Party Indication Lamp TypeChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan