TOA Electronics manual CP-63 DIP Switches for Function Selection, Sw-A Sw-B Sw-C Sw-D

Page 17

4. CP-63 DIP SWITCHES FOR FUNCTION SELECTION

SW-A

SW-B

SW-C

SW-D

Functions

Link Selection; Link No. 0 ~ 3

Link Selection; Link No. 4 ~ 7

Link Selection; Link No. 8 ~ 1 1

Link Selection; Link No. 12 ~ 15

Time Interval Adjustment before Paging

Pre-announcement tone

Conference

Call Transfer, Paging during Normal Call Exective Priority (High priority)

Paging

Secretary Transfer, Group Hunting

System Size Selection

Selectable Numbering Schedules

100-400-700/200-470

-740

Selectable Dial Operation for Paging Response

Not

used

 

Not

used

 

Selectable Total Paging Zone Capacity 45/21

Not used

Stations Allowed Access to All Call, Conference and General Purpose Control

Not used

Not used

Group Blocking

Programmable Station Numbering

Pager

Switch OFF

Not Activate

Not Activate

Not Activate

Not Activate

None

Not Activate

Not Activate

Not Activate

Not Activate

Not Activate

EX-610

No.200 (20)~

(OFF)

(OFF)

21Zones (OFF)

Not Activate (OFF)

(OFF)

Not Activate

Not Activate

Not Activate

Switch ON

Activate

Activate

Activate

Activate

1 sec

Activate

Activate

Activate

Activate

Activate

EX-620

No. 100 (10)~

——

——

45Zones

——

Activate

——

——

Activate

Activate

Activate

SW-E

1 x Exchange

2 x Exchange

 

3 x Exchange

 

EX-1

EX-2A

EX-2B

EX-3A

EX-3B

EX-3C

OFF

OFF

OFF

ON

ON

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

ON

Memory of Calling Party Indication (Lamp type)

Without memory

With memory

Tone of called Mode at Privacy Sw.ON

Privacy

Continuous calling

Continuous Calling Tone (No. 200 Programming)

Not Activate

Activate

Functions

Switch OFF

Switch ON

Note: *1 Be sure to place the SW-B-4 (Paging) switch in the ON position when Paging and its allied

functions are used.

*2 "45 zones" made possible with 3 exchanges are used when EX-610/620 is connected to

EX-630 (not yet available for sale) A: Zone 01 ~ 07, B: Zone 16 ~ 22, C: Zone 31 ~ 37

*3 When set to the "Active" position, the lamp continues to light to indicate all the stations that

have called while the called party has been in the "Privacy" or "Busy" mode.

— 16 —

Image 17
Contents CP-63 Contents Installation Hand Book of EXES-6000 Introduction to the Installation Manual for EXES-6000Installation Hand Book of Exchange Required Installation Hand Book SystemsFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack Function of the Central Processing Unit CP-63 TIE-LINE Connection of the ExchangesBlock diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange Fixed MINI-JUMPER JP2 Function Select Switches SW-ESW-C SW-B Initial CP-63 SET UP Check of ROM & NMOS-RAM No calls on the system Trouble ShootingTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link SW-A SW-B SW-C SW-D CP-63 DIP Switches for Function SelectionON/OFF Clearance at one time Function Code Table for Station no ProgrammingOFF Programming of SystemOperating for Programming Programming of each FunctionYES Station no Programming for Each FunctionExecutive Priority Function Code 50 Highest Priority Continuous Calling Tone Step Continuous Calling Tone Function CodeStations Allowed Access to ALL Call Step Stations Allowed Access to ALL Call Function CodeStations Allowed Access to Conference Step Stations Allowed Access to Conference Function CodeHandset Substations Allowed Access to Paging Step Automatic Access to Paging Function CodeCall by Dialing Picking up the Handset Complementary NotesStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Step Stations Allowed Access to MAKE/BREAK Output Function CodeTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship MASTER/SUB Relationship Function CodeGroup Hunting Function Code Establishment of Each Paging Zone Paging Zone Function CodeEstablishment of Each Group Group BlockingRegistration of station numbers having indication panel Calling Party Indication Lamp Type Function CodeAllowing Calls Among Groups Group Blocking 2 Allowing Calls Among Groups Function CodeAllowing Access to Paging Zones Programmable Station Numbering Programmable Station Numbering Function CodeProgramming of Single Station Number Restriction of programmable station numbering Programming of Serial Station NumbersInitial Programming Programming Data TableInitial Programming of the Exchange Clearance of Each Function at a TimeFunction Function Table for the SystemFunction Table for Stations Programming DataProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Channel Select Cable YR-802 or YR-806DIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Channel Selection Functions Explanation of Data Transmitting Unit Output ChannelsDescription ApplicationChannel 0 CH In/Out Annunciation Explanation of Data Receiving Unit Output DataChannel Select Switch Channel 2 CH Calling Party Indication Lamp Type Channel Select SwitchChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan