TOA Electronics CP-63 manual Complementary Notes, Call by Dialing Picking up the Handset

Page 27
or by

COMPLEMENTARY NOTES

(1) Automatic Access to Paging

This function facilitates Paging / Paging response from a

Substation TL-600S. Just picking up the Handset of Sub-

station automatically activates Paging or Paging Response mode.

(2)Required Programming for Automatic Access to Paging from Handset Substation.

2-1) First, connect a Master Station HF-600M or TL-600M in place of a Substation TL-600S.

2-2) Program at that station a necessary function for Single Digit

Dialing such as Paging, Paging Response, Personal Number Call or etc.

2-3) Then, replace the Master Station with a Substation TL-600S.

2-4) Program "Automatic Access to Paging from Handset Substation

(Function Code 54)" at the Station No. 200 according to the

programming instructions.

(3) Single Digit Dialing and Automatic Access to Paging

By programming "Single Digit Dialing" at any master station, a

single touch of the dial activates "Station Call", "Personal Number Call", "Paging" or "Paging Response" mode. But in using a TL-600S and a HF-600S, "Automatic Access to Paging from Handset Substation" function cannot be adopted only by programming "Single Digit Dialing" at the station. It also

requires the programming for Function Code 54 at No. 200 Station.

(4)A call to Master Station from Handset or Hands-free/ Handset Substation

"Master/Sub Relationship (Function Code 61)" can be

programmed into Handset Substation TL-600S or Hands-free/

Handset Substation HF-600S etc., where you can call the relative Master Station by a single touch of the dial

picking up the Handset.

In activating a mode with Hands-free/Handset Substation HF-600S by picking up the Handset, "Privacy" switch on the Station is to be "ON" position.

(5) Call by Dialing

& Picking up the Handset

 

 

 

 

Call to Master Station

 

 

 

By dialing

By picking up

 

 

Necessary

Handset

Function

 

 

 

Programming

at

at

 

 

 

 

 

HF-620Sor

TL-600S or

 

 

 

HF-600S

HF-600S

 

 

 

 

(Privacy SW. ON)

Single Digit

 

Single Digit

 

 

 

Registration

 

 

Dialing

 

 

 

 

at Station

 

 

 

 

 

 

Master/sub

 

Programming at

 

 

Station No. 200

 

 

Relationship

 

 

 

(Function Code 61)

 

 

 

 

 

 

 

1.

Single Digit

 

 

 

 

Registration

 

 

Automatic Access to Paging

 

at Station

 

 

Paging (or Calling)

 

 

 

 

from Handset Substation

2.

Programming at

 

 

 

 

Station No.200

 

 

 

 

(Function Code 54)

 

 

Note.

Paging Call, Paging Response

or Personal Number Call

By dialing

By picking up

Handset

 

at

at

HF-620S or

TL-600S or

HF-600S

HF-600S

 

(Privacy SW. ON)

Possible

Impossible

Possible but usually Not to be used Possible across the tie-lined exchange. Impossible across the tie-lined exchange.

— 26 —

Image 27
Contents CP-63 Contents Required Installation Hand Book Systems Introduction to the Installation Manual for EXES-6000Installation Hand Book of EXES-6000 Installation Hand Book of ExchangeFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack Function of the Central Processing Unit CP-63 TIE-LINE Connection of the ExchangesBlock diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange Function Select Switches SW-E SW-C SW-BFixed MINI-JUMPER JP2 Initial CP-63 SET UP Check of ROM & NMOS-RAM No calls on the system Trouble ShootingTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link SW-A SW-B SW-C SW-D CP-63 DIP Switches for Function SelectionON/OFF Clearance at one time Function Code Table for Station no ProgrammingOFF Programming of SystemOperating for Programming Programming of each FunctionStation no Programming for Each Function Executive Priority Function Code 50 Highest PriorityYES Continuous Calling Tone Step Continuous Calling Tone Function CodeStations Allowed Access to ALL Call Step Stations Allowed Access to ALL Call Function CodeStations Allowed Access to Conference Step Stations Allowed Access to Conference Function CodeHandset Substations Allowed Access to Paging Step Automatic Access to Paging Function CodeCall by Dialing Picking up the Handset Complementary NotesStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Step Stations Allowed Access to MAKE/BREAK Output Function CodeTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship MASTER/SUB Relationship Function CodeGroup Hunting Function Code Establishment of Each Paging Zone Paging Zone Function CodeEstablishment of Each Group Group BlockingRegistration of station numbers having indication panel Calling Party Indication Lamp Type Function CodeAllowing Calls Among Groups Group Blocking 2 Allowing Calls Among Groups Function CodeAllowing Access to Paging Zones Programmable Station Numbering Function Code Programming of Single Station NumberProgrammable Station Numbering Restriction of programmable station numbering Programming of Serial Station NumbersClearance of Each Function at a Time Programming Data TableInitial Programming Initial Programming of the ExchangeFunction Function Table for the SystemFunction Table for Stations Programming DataProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Channel Select Cable YR-802 or YR-806DIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Application Explanation of Data Transmitting Unit Output ChannelsChannel Selection Functions DescriptionChannel 0 CH In/Out Annunciation Explanation of Data Receiving Unit Output DataChannel Select Switch Channel 2 CH Calling Party Indication Lamp Type Channel Select SwitchChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan