FUNCTION CODE TABLE FOR STATION NO. 200 PROGRAMMING

B. Programming of System

Function

Function

Function

 

Remarks

 

 

Group

Code

 

 

 

 

 

 

 

 

 

 

 

The following standard station numbering

 

 

 

schedules of the exchanges A, B and C are

 

 

 

obtainable. (Hardwired station number)

 

Numbering Schedules

 

SW-C-1

A

B

C

 

of Tie-line System

 

OFF

200~

470~

740~

 

 

 

 

First station number

40

ON

100~

400~

700 ~

 

set-up in each

 

 

 

 

 

 

 

 

 

 

exchange

Operating for Programming

Initially

Programmed

Mode

Standard

Station Numbering A/B/C= 200/470/740

or

S

Selection of Calling Tone

41

Selection of Paging

The first station number of each exchange in order of the exchanges, A, B and C can be set as any of the following numbers:

100/200/300/400/500/600/700/800/900

(Hardwired station number)

Two different calling tones, single note tone or trill note tone, are available in selection for the Hands-free system except the continuous calling tone.

First Station No. First Station No. of Exchange "A" of Exchange "B" 1 ~ 8 (First digit) 2 ~ 9 (First digit)

0:Without Calling Tone

1:Single Note Tone (0.2 sec.)

2:Trill note Tone (0.3 sec.)

First Station No.

of Exchange "C"

3 ~ 9 (First digit)

A/B/C=

100/400/700

Trill note Tone (0.3 sec.)

Paging

Pre-announcement42 Tone Duration

Time-out Conversation

45

Time-out Paging Call

46

You can select the length of time of paging pre-announcement tone.

Programming is possible so that stations can be disconnected automatically from the speech path in the unit of Minute and the Hurry-upSignal Tone can be heard 10 seconds before the disconnection.

Programming is possible so that stations can be disconnected automatically from the Paging circuit in the unit of Minute and the Hurry-upSignal Tone can be heard 10 seconds before the disconnection.

0:Without Paging pre-announcement Tone

1:Paging Pre-announcement Tone (1 sec.)

2:Paging Pre-announcement Tone (2 sec.)

00:Without Time-out function

01~99: Length limited (minute)

00:Without Time-out function 01~99: Length limited (minute)

Pre-announce-

ment Tone (2 sec.)

Without

Time-out

Without

Time-out

— 19 —

Image 20
Contents CP-63 Contents Introduction to the Installation Manual for EXES-6000 Installation Hand Book of EXES-6000Installation Hand Book of Exchange Required Installation Hand Book SystemsFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack TIE-LINE Connection of the Exchanges Function of the Central Processing Unit CP-63Block diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange Fixed MINI-JUMPER JP2 Function Select Switches SW-ESW-C SW-B Initial CP-63 SET UP Trouble Shooting Check of ROM & NMOS-RAM No calls on the systemTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link CP-63 DIP Switches for Function Selection SW-A SW-B SW-C SW-DON/OFF Function Code Table for Station no Programming Clearance at one timeProgramming of System OFFProgramming of each Function Operating for ProgrammingYES Station no Programming for Each FunctionExecutive Priority Function Code 50 Highest Priority Continuous Calling Tone Function Code Continuous Calling Tone StepStations Allowed Access to ALL Call Function Code Stations Allowed Access to ALL Call StepStations Allowed Access to Conference Function Code Stations Allowed Access to Conference StepAutomatic Access to Paging Function Code Handset Substations Allowed Access to Paging StepComplementary Notes Call by Dialing Picking up the HandsetStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Function Code Stations Allowed Access to MAKE/BREAK Output StepTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship Function Code MASTER/SUB RelationshipGroup Hunting Function Code Paging Zone Function Code Establishment of Each Paging ZoneGroup Blocking Establishment of Each GroupCalling Party Indication Lamp Type Function Code Registration of station numbers having indication panelGroup Blocking 2 Allowing Calls Among Groups Function Code Allowing Calls Among GroupsAllowing Access to Paging Zones Programmable Station Numbering Programmable Station Numbering Function CodeProgramming of Single Station Number Programming of Serial Station Numbers Restriction of programmable station numberingProgramming Data Table Initial ProgrammingInitial Programming of the Exchange Clearance of Each Function at a TimeFunction Table for the System FunctionProgramming Data Function Table for StationsProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Cable YR-802 or YR-806 Channel SelectDIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Explanation of Data Transmitting Unit Output Channels Channel Selection FunctionsDescription ApplicationExplanation of Data Receiving Unit Output Data Channel 0 CH In/Out AnnunciationChannel Select Switch Channel Select Switch Channel 2 CH Calling Party Indication Lamp TypeChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan