TOA Electronics CP-63 manual Explanation of Data Transmitting Unit Output Channels, Description

Page 53

12. EXPLANATION OF DATA TRANSMITTING UNIT OUTPUT CHANNELS

CHANNEL SELECTION

FUNCTIONS

IN/OUT Annunciation

DESCRIPTION

Personel in and out registration can be accomplished at any Master sta- tion by using personal numbers. Max. 500 IN/OUT annunciations may be done. (All the 3 exchanges provided the same indication)

APPLICATION

• IN/OUT Annunciation

(1 ) One-shot Make Output (50 contacts)

(2)Make/Break Output (100 contacts)

(3)8 Selectable Make Output (9 unit blocks)

(4)Decimal Output

(9 unit blocks)

(5)4 Decimal digits output (9 unit blocks)

(6)Pager Control Output (64 contacts)

Calling Party Indication (1) (One Station; One Lamp)

Calling Party Indication (2) (One Station; One Lamp)

One-shot make contacts can be avail-

able at any Master station.

*1

Make/Break contacts can be available at any Master station. *1

One contact out of 8 selectable make outputs is obtained. "Clear" opera- tion makes ail 8 relays break. *1

10 Selectable Decimal Outputs are available with 7 segments LEDs. *1

Indicate by 7 segments LEDs. *1

Make output (64 contacts) are avail- able for pager control. *2

Max. 120-Calling station numbers can be indicated when designated called station with Display Board is called. The numbers of called stations having an indication panel can be program- med at No. 200 station. (Only the calling stations within the same exchange can be indicated by a lamp)

ITV camera selection

VTR control

Door Remote

IN/OUT Annunciation

Destination indication

VTR control

Room condition indication.

Prescription annunciation

Pager

The group number of called station (s). No. 1 ~ 4

The group number of called station (s). No. 5 ~ 8

Note.

*1.Each exchange has an independent control system, and it is impossible to control the Data Transmitting Unit of the other exchange form the station connected to the different exchange.

*2. Can only be connected to the exchange A (Station No. 200 ~

327). It is impossible to call the pagers from any station not connected to the exchange A. However, the response to a pager call is possible from any station regardless of the exchange it is connected to.

— 52 —

Image 53
Contents CP-63 Contents Installation Hand Book of EXES-6000 Introduction to the Installation Manual for EXES-6000Installation Hand Book of Exchange Required Installation Hand Book SystemsFunctions Which Require Additional Units Example of Exchange Mounted on Intercom Cabinet Rack Function of the Central Processing Unit CP-63 TIE-LINE Connection of the ExchangesBlock diagram for tielined exchanges Relationship between the PI unit and the LM unit Wiring for TIE-LINE Connection of the Exchanges Example of connection of EX-620 exchange Example of connection of EX-620 exchange Fixed MINI-JUMPER JP2 Function Select Switches SW-ESW-C SW-B Initial CP-63 SET UP Check of ROM & NMOS-RAM No calls on the system Trouble ShootingTie-line for 3 exchanges Reference for Connection Link Number between DL and Tl Link SW-A SW-B SW-C SW-D CP-63 DIP Switches for Function SelectionON/OFF Clearance at one time Function Code Table for Station no ProgrammingOFF Programming of SystemOperating for Programming Programming of each FunctionYES Station no Programming for Each FunctionExecutive Priority Function Code 50 Highest Priority Continuous Calling Tone Step Continuous Calling Tone Function CodeStations Allowed Access to ALL Call Step Stations Allowed Access to ALL Call Function CodeStations Allowed Access to Conference Step Stations Allowed Access to Conference Function CodeHandset Substations Allowed Access to Paging Step Automatic Access to Paging Function CodeCall by Dialing Picking up the Handset Complementary NotesStation Allowed Access to ONE Shot Make Output Step Stations Allowed Access to MAKE/BREAK Output Step Stations Allowed Access to MAKE/BREAK Output Function CodeTouch Function Code New Registration? Stations Allowed Access to 4 Decimal Digits Output Step Secretary Transfer Function Code MASTER/SUB Relationship MASTER/SUB Relationship Function CodeGroup Hunting Function Code Establishment of Each Paging Zone Paging Zone Function CodeEstablishment of Each Group Group BlockingRegistration of station numbers having indication panel Calling Party Indication Lamp Type Function CodeAllowing Calls Among Groups Group Blocking 2 Allowing Calls Among Groups Function CodeAllowing Access to Paging Zones Programmable Station Numbering Programmable Station Numbering Function CodeProgramming of Single Station Number Restriction of programmable station numbering Programming of Serial Station NumbersInitial Programming Programming Data TableInitial Programming of the Exchange Clearance of Each Function at a TimeFunction Function Table for the SystemFunction Table for Stations Programming DataProgrammingdatatable For Tie-line Unit EX-620 Station Numbers Table for Calling Party Indication Lamp Type Individual Stations Channel Select Cable YR-802 or YR-806DIP Switch Table for Data Transmitting and Receiving Units YR-810 YR-802 Channel Selection Functions Explanation of Data Transmitting Unit Output ChannelsDescription ApplicationChannel 0 CH In/Out Annunciation Explanation of Data Receiving Unit Output DataChannel Select Switch Channel 2 CH Calling Party Indication Lamp Type Channel Select SwitchChannel 3 CH Calling Party Indication Lamp Type Necessary module units KOBE, Japan