| Installing the VoIP V3 Indoor Intercom 33 | |
| Configure the SIP Parameters | |
Table | ||
|
|
|
Web Page Item | Description | |
|
|
|
Call Disconnection |
|
|
|
|
|
Terminate call after delay (in seconds) | Type the desired number of seconds that you want to transpire | |
| after a connection delay before a call is terminated. | |
| Note: A value of 0 will disable this function. | |
|
|
|
RTP Settings |
|
|
|
|
|
RTP Port (even) | Specify the port number used for the RTP stream after | |
| establishing a SIP call. This port number has to be an even | |
| number and defaults to 10500. | |
|
|
|
Dial Out Settings |
|
|
|
|
|
Dial Out Extension | Type the dial out extension number (64 character limit). | |
| Note: For information about | |
| DTMF tones, see Section 2.4.6.1, "Dial Out Extension Strings | |
| and DTMF Tones (using rfc2833)". | |
|
|
|
Extension ID | Type the desired Extension ID (64 character limit). | |
|
|
|
| Click the Save button to save your configuration settings. | |
| Note: You need to reboot for changes to take effect. | |
|
|
|
| Click on the Reboot button to reboot the system. |
3.After changing the parameters, click Save Settings.
2.4.6.1Dial Out Extension Strings and DTMF Tones (using rfc2833)
On the SIP Configuration Page, dial out extensions support the addition of comma delimited pauses and sending additional DTMF tones (using rfc2833). The first comma will pause three seconds after a call is first established with a remote device. Subsequent commas will pause for 2 seconds. A pause of one second will be sent after each numerical digit.
| Table |
|
|
Extension String | Resulting Action |
|
|
302 | Dial out extension 302 and establish a call |
|
|
302,2 | Dial out extension 302 and establish a call, wait 3 seconds then send the |
| DTMF tone '2' |
|
|
302,25,,,4,,1 | Dial out extension 302 and establish a call, wait 3 seconds then send the |
| DTMF tone '2', send out DTMF tone 5, wait 6 seconds, send out DTMF |
| tone 4, wait 4 seconds, send out DTMF tone 1 |
|
|
Note The maximum number of total characters in the
Operations Guide | 930500E | CyberData Corporation |