CyberData 11113 manual Dial Out Extension Strings and Dtmf Tones using rfc2833, Call Disconnection

Page 40

 

Installing the VoIP V3 Indoor Intercom 33

 

Configure the SIP Parameters

Table 2-9. SIP Configuration Parameters (continued)

 

 

 

Web Page Item

Description

 

 

 

Call Disconnection

 

 

 

 

 

Terminate call after delay (in seconds)

Type the desired number of seconds that you want to transpire

 

after a connection delay before a call is terminated.

 

Note: A value of 0 will disable this function.

 

 

 

RTP Settings

 

 

 

 

 

RTP Port (even)

Specify the port number used for the RTP stream after

 

establishing a SIP call. This port number has to be an even

 

number and defaults to 10500.

 

 

 

Dial Out Settings

 

 

 

 

 

Dial Out Extension

Type the dial out extension number (64 character limit).

 

Note: For information about dial-out extension strings and

 

DTMF tones, see Section 2.4.6.1, "Dial Out Extension Strings

 

and DTMF Tones (using rfc2833)".

 

 

 

Extension ID

Type the desired Extension ID (64 character limit).

 

 

 

 

Click the Save button to save your configuration settings.

 

Note: You need to reboot for changes to take effect.

 

 

 

 

Click on the Reboot button to reboot the system.

3.After changing the parameters, click Save Settings.

2.4.6.1Dial Out Extension Strings and DTMF Tones (using rfc2833)

On the SIP Configuration Page, dial out extensions support the addition of comma delimited pauses and sending additional DTMF tones (using rfc2833). The first comma will pause three seconds after a call is first established with a remote device. Subsequent commas will pause for 2 seconds. A pause of one second will be sent after each numerical digit.

 

Table 2-10. Examples of Dial-Out Extension Strings

 

 

Extension String

Resulting Action

 

 

302

Dial out extension 302 and establish a call

 

 

302,2

Dial out extension 302 and establish a call, wait 3 seconds then send the

 

DTMF tone '2'

 

 

302,25,,,4,,1

Dial out extension 302 and establish a call, wait 3 seconds then send the

 

DTMF tone '2', send out DTMF tone 5, wait 6 seconds, send out DTMF

 

tone 4, wait 4 seconds, send out DTMF tone 1

 

 

Note The maximum number of total characters in the dial-out field is 64.

Operations Guide

930500E

CyberData Corporation

Image 40
Contents VoIP V3 Indoor Intercom Operations Guide Replaces #011111 Document 930500E for Firmware VersionCopyright Notice Important Safety Instructions Pictorial Alert Icons Hazard LevelsRevision Information Contents Index Appendix C Troubleshooting/Technical SupportA Windows Environment Product Overview How to Identify This ProductModel number Generic PoE Switch Typical System InstallationDoor Strike VoIP Intercom IP Phone IP PBX Server PoE 802.3af-enabled Powered-over-Ethernet Product FeaturesConcurrent SIP and multicast paging Supported SIP Servers Supported ProtocolsIntercom supports Product Specifications This number replaces the 011111 numberDimensions Dimensions-Unit DimensionsR0.438 R11.1 R0.100 Plcs PCB Dimensions and Intrusion Sensor Range Installing the VoIP V3 Indoor Intercom Parts ListIntercom Mounting Accessory Kit 1illustrates the VoIP V3 Indoor Intercom partsInformation about the functionality Call Button Intercom ComponentsSpeaker Call Button and the Call Button LED Calling with the The Call ButtonCall Button LED Function Call Button and Call Button LEDIntercom Connections Intercom Setup= Door Sense Ground Reference Connecting the Intercom to the Auxiliary Relay Auxiliary Relay Wiring Contacts Example of External Relay not suppliedIdentifying the VoIP Intercom Connectors J10Factory Only-Reset Factory Only-Boot ModeJP10 Disables the intrusion sensor when installed PoE Network Connection RJ-45 ethernetNetwork Connectivity, and Data Rate Link ActivityEthernet cable Network Connector Verify Network ActivityRtfm Button Announcing the IP AddressAdjust the Volume Restoring the Factory Default SettingsFactory Default Settings Configure the Intercom ParametersIP Addressing Intercom Web Page Navigation Log in to the Configuration Home 13. Home Device Settings Current SettingsConfigure the Device 14. Device ConfigurationVolume Settings Relay SettingsMiscellaneous Settings CallAfter changing the parameters, click the Save button Configure the Network Parameters 15. Network Configuration Stored Network Settings Dhcp Timeout Current Network Settings Select either Dhcp IP Addressing or Static IP Addressing byConfigure the SIP Parameters Click SIP Config to open the SIP Configuration page FigureEnable SIP Operation Enables or disables SIP operation SIP SettingsIf all of the Primary SIP Server and Backup SIP Server Backup SIP Server 1 and Backup SIP Server 2 fields blankDial Out Extension Strings and Dtmf Tones using rfc2833 After changing the parameters, click Save SettingsRTP Settings Dial Out SettingsPoint-to-Point Configuration Intercom is set to not register with a SiP serverDelayed Dtmf Configure the Nightringer Parameters 18. Nightringer Configuration SetupNightringer Settings After changing the parameters, click on the Save buttonConfigure the Sensor Configuration Parameters 19. Sensor Configuration Door Sensor Settings Intrusion Sensor SettingsConfigure the Multicast Parameters 20. Multicast ConfigurationAssigning Priority 9.1, Assigning Priority for more detailsConfigure the Audio Configuration Parameters 21. Audio Configuration22. Audio Configuration Audio Files User-created Audio Files 23. AudacityWAV Microsoft signed 16 bit PCM WAV Microsoft signed 16 bit PCMConfigure the Event Parameters 16shows the web page items on the Event ConfigurationRemote Event Server When selected, Call Terminated Events are enabledEvents Example Packets for Events Operations Guide 930500E CyberData Corporation User-Agent CyberData/1.0.0 Content-Length Configure the Autoprovisioning Parameters 27. Autoprovisioning ConfigurationEnable Autoprovisioning AutoprovisioningGet Autoprovisioning from Dhcp Autoprovisioning Server IP AddressAutoprovisioning Would be a valid autoprovisioning fileOperations Guide 930500E CyberData Corporation Autoprovisioned Audio Files Upgrade the Firmware and Reboot the Intercom Uploading the Firmware18. Firmware Upgrade Parameters Web Page Item Description File UploadClick Reboot -29. a normal restart will occur Reboot the IntercomReboot Command Interface Command Interface Post CommandsPlay the Intrusion Sensor Triggered audio file Wget Play the 4 audio file WgetPlay the Door Ajar audio file Wget Play the Night Ring audio file Wget Delete the Door Ajar audio file Wget Deletedoorajar=yes Delete the Night Ring audio file WgetAppendix a Mounting the Indoor Intercom Wall Mounting ComponentsQuantity Part Name Sheet Metal ScrewFigure A-1shows how to properly connect the VoIP Intercom Cable ConnectionsWall Mounting Option Figure A-2shows a wall mounting optionWall Cutout Dimensions Dimensions are in Inches MillimeterGang Box Option Top Cable Entry SlotPCB Dimensions Appendix B Setting up a Tftp Server Set up a Tftp ServerA Linux Environment A Windows EnvironmentFrequently Asked Questions FAQ Appendix C Troubleshooting/Technical SupportDocumentation Contact Information Warranty Warranty & RMA Returns within the United StatesWarranty & RMA Returns Outside of the United States Spare in the Air PolicyWarranty and RMA Returns Return and Restocking PolicyIndex NumericsIndex SIP Srst Yellow act light 18 yellow link light