TROUBLESHOOTING & REPAIR
MAIN TRANSFORMER REMOVAL & REPLACEMENT (continued)
FIGURE F.30 – PRIMARY THERMOSTAT LOCATION
TOP VIEW
THERMOSTAT
INSULATION
FRONT VIEW
TOC
TOC
10.Mount the primary thermostat to the lead end coil nose. See Figure F.30. Place a small amount of Lincoln Electric E1603 Epoxy between the coil nose and the coil insulation and between the insulation and the thermostat. Hold the thermostat in place with E2381 (.375” wide) tape. If nec- essary, after assembly protect the thermo- stat terminals with E2547 terminal boots.
11.If necessary, trim off excess secondary lead stickout and TIG weld the leads together. See Figure F.31.
Return to Section
Return to Section TOC
Return to Master
Return to Master TOC
FIGURE F.31 – SECONDARY LEAD TRIM AND WELD DETAIL
TIG WELD