| TROUBLESHOOTING & REPAIR |
| |
| TROUBLESHOOTING GUIDE | Observe Safety Guidelines | |
|
| detailed in the beginning of this manual. |
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED | |
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | |
|
|
|
|
| WELDING PROBLEMS |
|
|
Poor arc striking when using semi- | 1. Make sure the correct weld pro- | 1. | Check reed switch CR3 for |
automatic or automatic wire | cedures are being used. |
| proper operation. Switch |
feeders. | (Electrode, Gas, Etc.) |
| should be normally open until |
| 2. Check the welding cables for |
| weld current is established. |
|
|
| |
| loose or faulty connections. | 2. | The start board may be faulty. |
|
|
| Replace. |
|
| 3. | The control board may be |
|
|
| faulty. Replace. |
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call