TROUBLESHOOTING & REPAIR
RETEST AFTER REPAIR
Retest a machine:
•If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics. OR
•If you repair or replace any electrical components.
INPUT IDLE AMPS AND WATTS
Input volts/Phase/Hertz | Maximum Idle Amps | Maximum Idle KW |
200/3/60 | 10.9 | 1.2 |
208/3/60 | 10.5 | 1.2 |
220/3/60 | 9.9 | 1.2 |
230/3/60 | 9.5 | 1.2 |
380/3/60 | 5.8 | 1.2 |
400/3/60 | 5.5 | 1.2 |
415/3/60 | 5.3 | 1.2 |
440/3/60 | 5.0 | 1.2 |
460/3/60 | 4.8 | 1.2 |
500/3/60 | 4.4 | 1.2 |
575/3/60 | 3.8 | 1.2 |
200/3/50 | 19.8 | 1.3 |
220/3/50 | 18.0 | 1.3 |
230/3/50 | 17.2 | 1.3 |
380/3/50 | 10.4 | 1.3 |
400/3/50 | 9.9 | 1.3 |
415/3/50 | 9.5 | 1.3 |
440/3/50 | 9.0 | 1.3 |
500/3/50 | 7.9 | 1.3 |
|
|
|
OPEN CIRCUIT VOLTAGES
| Mode | Input Hertz | Open Circuit Volts | |
| Constant Current | 60 | 54/58 |
|
| Constant Current | 50 | 51/55 |
|
| Constant Voltage | 60 | 42.5/46.5 |
|
| (FCAW/GMAW) | 50 | 42.5/46.5 |
|
| Constant Voltage | 60 | 43.5/47.5 |
|
| (SUB ARC) | 50 | 43.5/47.5 |
|
| Auxiliary Output | 60 | 114/124 |
|
| Auxiliary Output | 50 | 109/119 |
|
| Auxiliary Output | 60 | 43.8/47.5 |
|
| Auxiliary Output | 50 | 42.0/45.6 |
|
|
|
|
|
|
IDEALARC