TROUBLESHOOTING & REPAIR | ||
Observe Safety Guidelines |
| TROUBLESHOOTING GUIDE |
detailed in the beginning of this manual. |
| |
|
|
|
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
|
|
|
| FUNCTION PROBLEMS |
|
The machine will not shut off when | 1. Make sure the | 1. Check the Input Power switch |
the power switch is put in the OFF | input lines are connected cor- | (S1) and the associated leads. |
position. | rectly to the | See Wiring Diagram. |
|
| 2. Perform the Input Contactor |
|
| Test. |
|
|
|
The Arc Control switch (S5) has no | 1. Make sure the correct process | 1. Check the Arc Control switch |
effect in CV (FCAW/GMAW) mode | and gas are being used. | (S5) for proper operation. |
when welding with the short circuit |
| 2. Check the welding Mode switch |
transfer process. |
| |
| (S4), the microswitches, and the | |
|
| |
|
| associated wiring. |
|
| 3. Check to make sure the output |
|
| choke control coil is not “open” |
|
| or grounded. See Wiring |
|
| Diagram. |
|
| 4. Check resistor R1. Normal |
|
| resistance is 15 ohms. |
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call