TROUBLESHOOTING & REPAIR |
| ||||
Observe Safety Guidelines |
|
|
| TROUBLESHOOTING GUIDE | |
detailed in the beginning of this manual. |
|
|
|
| |
|
|
|
| ||
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
| ||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | |||
|
|
|
| ||
| OUTPUT PROBLEMS |
|
| ||
The machine has minimum welding | 1. If remote control is being used, | 1. Check the Output Control | |||
output and no control. | set the Output Control switch | potentiometer (R4) and associ- | |||
| (S2) in the OUTPUT CONTROL | ated wiring. | See Wiring | ||
| “LOCAL” | position | and control | Diagram. |
|
| the weld | output | with the | 2. Check the welding Mode switch | |
| machine Control potentiometer | ||||
| (S4), the microswitches, and the | ||||
| (R4). If the problem is solved, | ||||
| associated wiring. |
| |||
| check the remote control unit |
| |||
|
|
| |||
| (or wire feeder) and associated | 3. Check the Output Control | |||
| control cable. |
| switch (S2) and | associated | |
| 2. Make certain the remote control | wiring. See Wiring Diagram. | |||
|
|
| |||
| leads (#75, #76 and #77) are not | 4. Perform the Main Transformer | |||
| grounded to the positive weld- | Test. |
| ||
| ing output. |
| 5. Perform the SCR/Diode Rec- | ||
|
|
|
| ||
| 3. Make certain the | tifier Bridge Test. |
| ||
| input voltage is correct and | 6. The control board may be faulty. | |||
| matches the machine rating and | ||||
| Replace. |
| |||
| the reconnect panel. |
| |||
|
|
| |||
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call