| TROUBLESHOOTING & REPAIR | |
| TROUBLESHOOTING GUIDE | Observe Safety Guidelines |
|
| detailed in the beginning of this manual. |
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED | |
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | |
|
|
|
|
| OUTPUT PROBLEMS |
|
|
The machine is dead – no output – | 1. Check the | 1. Perform the Input Contactor | |
no fan – the pilot light is lit. | voltage at the machine. Input | Test. |
|
| voltage must match the rating | 2. Check the associated leads, for | |
| plate and the reconnect panel. | ||
| loose or | faulty connections, | |
|
| ||
| 2. Check for blown or missing | between | the input contactor |
| fuses in the input lines. | (CR1), the reconnect panel and | |
|
| the main | transformer. See |
|
| Wiring Diagram. | |
|
| 3. Perform the Main Transformer | |
|
| Test. |
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call