TROUBLESHOOTING & REPAIR
RETEST AFTER REPAIR (continued)
MAXIMUM ACCEPTABLE OUTPUT VOLTAGE-
AT MINIMUM OUPUT SETTINGS
Mode | Control Settings | Load |
Constant Current | Output Control and Arc Force | Under 70 Amps @ 0 to 3 Volts |
| Control at Minimum |
|
Constant Voltage | Output Control at Minimum | 120 Amps @ 6 to 12 Volts |
(FCAW/GMAW) |
|
|
|
|
|
MINIMUM ACCEPTABLE OUTPUT VOLTAGE-
AT MAXIMUM OUTPUT SETTINGS
Mode | Control Settings | Load |
Constant Current | Output Control at Maximum | 525 Amps @ 41.5 Volts (Min) |
Constant Voltage | Output Control at Maximum | 525 Amps @ 41.5 Volts (Min) |
(FCAW/GMAW) |
|
|
Constant Voltage | Output Control at Maximum | 525 Amps @ 41.5 Volts (Min) |
(SUB ARC) |
|
|
|
|
|