TROUBLESHOOTING AND REPAIR |
| |||||
|
|
|
|
| ||
|
|
|
| |||
Observe Safety Guidelines detailed in the beginning of this manual. |
|
|
| |||
|
|
|
|
|
| |
| PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
| |
| (SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION | ||
|
|
|
|
|
|
|
|
|
| FUNCTION PROBLEMS |
|
|
|
No current regulation in the Stick | 1. | Make sure the machine is | 1. The Superimposition Board may | |||
mode. Low open circuit voltage. |
| and configured correctly for the | be faulty |
|
| |
|
|
| Stick mode, |
|
|
|
|
|
|
| 2. The Output Module Transistor | ||
|
|
|
| Board may be faulty. See the | ||
|
|
|
| Secondary | Output | Board |
|
|
|
| Assembly | Test and | Wiring |
|
|
|
| Diagram. |
|
|
|
|
|
| |||
There is no response to changes to | 1. | Make sure the correct input volt- | 1. The Control/Display board may | |||
the output control settings. No cur- |
| age is applied to the machine. | be faulty. |
|
| |
rent regulation in all modes. |
| 230 or 115VAC. |
|
|
| |
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call