Lincoln Electric SVM161-A service manual Output Connections, Work Cable Connection

Page 14

A-6

INSTALLATION

A-6

 

Return to Master TOC

TOC

OUTPUT CONNECTIONS

WARNING

ELECTRIC SHOCK can kill.

Keep the electrode holder, TIG torch and cable insulation in good condition and in place.

Do not touch electrically live parts or electrode with skin or wet cloth- ing.

Insulate yourself from work and ground.

Turn the input line Switch on the Invertec® V205- T AC/DC™ “off” before connecting or discon- necting output cables or other equipment.

------------------------------------------------------------------------

This unit does not include a TIG torch, but one may be purchased separately. The accessories section of this manual lists a number of Lincoln Electric TIG torches, and TIG Torch Starter Packs that are recommended for use with this machine; however, any similar TIG torch can be used. To attach the Twist-Mate Plug to a Lincoln Torch, slide the rubber boot onto the torch cable (enlarge the boot opening if necessary), screw the fit- ting on the torch cable into the brass connector snugly and slide the boot back over the brass connector.

TIG ADAPTER

STRAIN RELIEF BOOT

RETAINING COMPOUND

TIG TORCH POWER CABLE WITH GAS FITING

OUTPUT CONNECTION FOR STICK WELDING (FIGURE A.2)

Return to Section TOC

Return to Section TOC

Return to Master

OUTPUT AND GAS CONNECTION FOR TIG WELDING (FIGURE A.1)

The TIG Torch Twist-Mate and work cable Twist-Mate Connectors are supplied with the welder. To connect the cables, turn the Power Switch “OFF”. Connect the torch cable Twist-Mate plug into the DC(-) Electrode/Gas Output Receptacle on the front of the welder and turn it clockwise until snug,(Do not Overtighten). This is a quick connect terminal and also provides the gas connection for the shielding gas to the torch.

First determine the proper electrode polarity for the electrode to be used. Consult the electrode data for this information. Then connect the output cables to the output terminals corresponding to this polarity. For instance, for DC(+) welding, connect the electrode cable (which is connected to the electrode holder) to the “+” output terminal and the work cable (which is connected to the work clamp) to the “-” output terminal. Insert the connector with the key lining up with the key- way, and rotate clockwise; until the connection is snug. Do not over tighten.

Return to Section TOC

to Section TOC

Return to Master TOC

to Master TOC

WARNING

To avoid receiving a high frequency shock, keep the TIG torch and cable insulation in good condi- tion.

___________________________________________

WORK CABLE CONNECTION

Next, connect the work cable to the “+” output terminal in the same way. To minimize high frequency interfer- ence, refer to Machine Grounding and High Frequency Interference Protection section of this manual for the proper procedure on grounding the work clamp and work piece.

FIGURE A.1

TIG TORCH

-

+

FIGURE A.2

WORK CABLE

WORK CABLE

STICK ELECTRODE

HOLDER

-

+

Return

Return

WORK CABLE

WORK CLAMP

 

INVERTEC® V205-T AC/DC™

Image 14
Contents Invertec V205-T AC/DC Safety Invertec V205-T AC/DCElectric Shock can kill ARC Rays can burn Can be dangerousCylinder may explode Powered equipmentWelding Cutting Sparks can cause fire or If damaged ExplosionPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcSafety Methods of Reducing Emissions Mains Supply Master Table of Contents for ALL Sections Table of Contents Installation Section Installation Operating Temperature Range Storage Temperature RangeTilting Select Suitable LocationStacking Environmental AreaReconnect Procedure Input Connections115V Input Attachment Plug Installation230V Input Engine Driven GeneratorWork Cable Connection Output ConnectionsOutput and GAS Connection for TIG Welding Figure A.1 Remote Control Connection Shielding GAS ConnectionInvertec V205-T AC/DC Table of Contents Operation Section General Description Safety InstructionsOperation Welding CapabilityOPERATIONB-3 Rear Control Panel Figure B.1Controls and Settings Figure B.2Step Diagram Local/Remote push button Selects the weldingTIG DC TIG AC SET UP Menu Indicator Parameter DefaultOutput Limitations Welding PolarityFigure B.7 Tips for AC TIG Welding Steel TIG WeldingCopper TIG Welding Filler MaterialAC TIG Welding Quick Start UP Protective GASDC TIG Welding Quick Start UP Table of Contents Accessories Section Compatible Equipment AccessoriesOptional Accessories Cable PlugsTable of Contents Maintenance Section Input Filter Capacitor Discharge Procedure MaintenanceSafety Precautions Routine Maintenance3MAINTENANCE Figure D.1 Major Component LocationsInvertec V205-T AC/DC 1TABLE of CONTENTS-THEORY of Operation Section E-1 Theory of Operation Input Board and BUS BoardMain Igbt Inverter Board Figure E.3 Main Igbt Inverter BoardOutput Module and Clamping Board Main TransformerOutput Module Transistor Board Superimposition BoardOutput Filter Board CONTROL/DISPLAY BoardHigh Frequency HF Board Insulated Gate Bipolar Transistor Igbt Operation Passive Active1TABLE of Contents Troubleshooting and Repair F-1 Troubleshooting and Repair HOW to USE Troubleshooting GuidePC Board Troubleshooting Procedures Electric Shock can killIgbt Perform the Input Filter Board Igbt Inverter Board Test Secondary Output Board Assembly Test See the Output Filter Troubleshooting and Repair External Diagnostics DisplayTroubleshooting and Repair Internal Diagnostics Figure F.2Internal Diagnostics LEDInvertec V205-T AC/DC Test Description Materials NeededInput Filter Capacitor Discharge Procedure Capacitor Solder Resistor PadsInput Filter Board Test Input Filter Board ProcedureInput Filter Board Test Input Filter Board Invertec V205-T AC/DC Main Igbt Inverter Board LOW Voltage Test Main Igbt Inverter Board LOW Voltage Test Figure F.6 Main Igbt Inverter Board LocationMain Igbt Inverter Board LOW Voltage Test LEDTP2 MF2 Figure F.7 Main Igbt Inverter Board LocationCONTROL/DISPLAY Board Test CONTROL/DISPLAY Board Test Figure F.8 CONTROL/DISPLAY Board LocationCN2 Figure F.9 CONTROL/DISPLAY Board LocationCN1 Figure F.10 Plugs CN1, CN2 & CN7BUS Board Test BUS Board Test Figure F.11 BUS Board LocationTable F.7 Plug CN4 Test Points Table F.5 Plug CN2 Test PointsTable F.6 Plug CN3 Test Points Table F.8 Plug CN7 Test PointsCN1 CN2 Main Inverter Board Power Factor Section Test Table F.11 Resistance Checks Main Inverter Board Power Factor Section TestTable F.10 Voltage Checks with 115 VAC Applied to Machine TP9 Gndpwr RL1 Invertec V205-T AC/DC Output Filter Board Test Output Filter Board Test Figure F.16 Output Filter Board LocationFigure F.17 Output Filter Board Plug Location Figure F.18 Output Filter Board Plug CN1Invertec V205-T AC/DC Secondary Output Board Assembly Test Secondary Output Board Assembly Test Figure F.19 Secondary Power Board LocationOFF GA-SA Mode Positive Meter Negative Meter Expected Reading Probe Table F.14 Output Diode Resistance CheckMain Inverter Board Welding Logic and Inverter Section Test Main Inverter Board Welding Logic and Inverter Section TestTable F.15 LED Function Table F.16 Feedback Voltage SignalsTable F.18 LED Check in Stick Mode Table F.17 Voltage Checks with 115 VAC Applied to MachineFigure F.22 Main Board Inverter Section TP9 Ground Power Invertec V205-T AC/DC Input Filter Board Removal and Replacement Input Filter Board Removal and Replacement Figure F.24 Input Filter Board LocationRV1 RV2 Invertec V205-T AC/DC Main Igbt Board Removal and Replacement Main Igbt Board Removal and Replacement Figure F.27 Main Igbt Board LocationRV1 RV2 CN4 RV3 RV4 CN5 RV5 RV7 RV6 Invertec V205-T AC/DC CONTROL/DISPLAY Board Removal and Replacement CONTROL/DISPLAY Board Removal and Replacement Figure F.29 CONTROL/DISPLAY Board LocationCN2 Invertec V205-T AC/DC Output Filter Board Removal and Replacement Removal and Replacement Figure F.32 Output Filter Board LocationPhillips Head Screws CN1 Output Diodes Removal and Replacement Output Diodes Removal and Replacement To Replace ANY of the Output Diodes D1, D2, D3 or D4Output Transistor Removal and Replacement Output Transistor Removal and Replacement Figure F.36 Output Transistor LocationPlug CN1 5mm Allen Bolts Invertec V205-T AC/DC Table of Contents Diagram Section ELECTriCaL DiaGramS