TROUBLESHOOTING AND REPAIR | ||||
|
| |||
|
|
|
|
|
|
| INTERNAL DIAGNOSTICS (Continued) |
| |
|
|
|
|
|
| LED | Definition | Normal Status Conditions |
|
|
|
|
|
|
| L1 | ON [Green] |
| |
|
|
|
|
|
| L2 | +15VDC supply by 15.14.316 for 15.14.316 logic part | ON [Green] |
|
|
|
|
|
|
| L3 | +5VDC supply by 15.14.316 for 15.14.316 logic part | ON [Green] |
|
|
|
|
|
|
| L4 | +24VDC supply by 15.14.316 for power front panel | ON [Green] |
|
|
|
|
|
|
| L5 | +48VDC supply by 15.14.316 for power front panel | ON [Green] |
|
|
|
|
|
|
| L6 | ON [Green] |
| |
|
| part |
|
|
| L7 | +15VDC supply by 15.14.316 for 15.14.316 UPFR | ON [Green] |
|
|
| part |
|
|
| L8 | Output power enabled (See “pot signal” & LED | STICK: ON [Green] |
|
|
| “Output”) | TIG: ON (torch trigger pulled) |
|
| L9 | Thermal Alarm | OFF = OK |
|
|
|
| ON = ALARM [Red] |
|
| L10 | UPFR on | Brightness proportional with |
|
|
|
| actual output current. |
|
| L11 | Gate MOS 11 active (output power enabled) | STICK: ON [Green] |
|
|
|
| TIG: ON (torch trigger pulled) |
|
| L12 | Gate MOS 12 active (output power enabled) | STICK: ON [Green] |
|
|
|
| TIG: ON (torch trigger pulled) |
|
| L13 | Gate MOS 16 active (output power enabled) | STICK: ON [Green] |
|
|
|
| TIG: ON (torch trigger pulled) |
|
| L14 | Gate MOS 15 active (output power enabled) | STICK: ON [Green] |
|
|
|
| TIG: ON (torch trigger pulled) |
|