TROUBLESHOOTING AND REPAIR | |||||
|
|
|
| ||
|
|
|
|
|
|
|
| BUS BOARD TEST (continued) |
| ||
|
| TABLE F.5 PLUG CN2 TEST POINTS |
| ||
|
|
|
|
|
|
| Wire # |
| Description | Expected Voltage |
|
|
|
|
|
|
|
| 21 |
| Thermal Trigger |
| |
|
|
|
|
|
|
| 22 |
| Output Hall Probe |
| |
|
|
|
|
|
|
| 23 |
| Hall Probe | +15 VDC |
|
|
|
|
|
|
|
| 24 |
| Ground Gate Switch B |
| |
|
|
|
|
|
|
| 26 |
| Ground Gate Switch A |
| |
|
|
|
|
|
|
| 27 |
| Thermal Trigger (AC Unit) |
| |
|
|
|
|
|
|
| 28 |
| Ground Hall Probe |
| |
|
|
|
|
|
|
| 29 |
| Hall Probe |
| |
|
|
|
|
|
|
| 30 |
| Gate Switch B |
| |
|
|
|
|
|
|
| 32 |
| Gate Switch A |
| |
|
|
|
|
|
|
|
| TABLE F.6 PLUG CN3 TEST POINTS |
| ||
|
|
|
|
|
|
| Wire # |
| Description | Expected Voltage |
|
|
|
|
|
|
|
| 61 |
| - Superimposition | 53.2 VDC(1) |
|
|
|
|
|
|
|
| 65 |
| Ground Superimposition |
| |
|
|
|
|
|
|
| 63 |
| + Superimposition | 53.2 VDC(1) |
|
|
|
|
|
|
|
|
|
| Welding Voltage | 52.6 VDC |
|
|
|
|
|
|
|
(1)In TIG mode only when Remote is pushed, comes on for two sec. then goes to zero. In STICK mode is present all the time.
TABLE F.7 PLUG CN4 TEST POINTS
| Wire # |
| Description | Expected Voltage |
|
|
|
|
|
41 |
| Front Panel Supply | 24 VDC | |
|
|
|
|
|
42 |
| Front Panel Supply Ground | ||
|
|
|
|
|
44 |
| HF Start | ||
|
|
|
|
|
45 |
| Front Panel Supply | 48 VDC | |
|
|
|
|
|
48 |
| HF Start Ground | ||
|
|
|
|
|
|
| TABLE F.8 PLUG CN7 TEST POINTS | ||
|
|
|
|
|
| Wire # |
| Description | Expected Voltage |
|
|
|
|
|
11 |
| Water Cooling Supply | ||
|
|
|
|
|
| Earth Cable |
| Water Cooling Supply | |
|
|
|
|
|
12 |
| Water Cooling Supply | ||
|
|
|
|
|
| Earth Cable |
| ||
|
|
|
|
|
|
| TABLE F.9 PLUG CN1 TEST POINTS | ||
|
|
|
|
|
| Wire # |
| Description | Expected Voltage |
|
|
|
|
|
| 5[+], |
| Fan | 24 VDC |
|
|
|
|
|