Pressure
Release
Valve
Check Valve

Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

Check Valve: When the air compressor is operating, the check valve is

“open”, allowing compressed air to enter the air tank. When the air compressor reaches “cut-out”

pressure, the check valve “closes”, allowing air pressure to remain inside the air tank.

Pressure

Release Valve: The pressure release valve, located on the side of

the pressure switch, is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches “cut-out” pressure or is shut off. The pressure release valve allows the motor to restart freely. When the motor stops running, air will be heard escaping from this valve for a few seconds. No air should be heard leaking when the motor is running, or continuous leaking after unit reaches “cut-out” pressure.

Air Intake Filter (not shown): This filter is designed to clean air coming into the pump. This filter must always be clean and ventilation openings free from obstructions. See "Maintenance".

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off lever to “OFF”.

Before Starting

Break-in Procedure

Serious damage may

result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "OFF" position.

NOTE: If quick connect is installed, pull coupler back until it clicks to prevent air from escaping through the quick connect.

On/Auto/Off

PressureSwitch

Switch

Safety

Valve

Outlet

PressureTank

GaugePressure

Gauge

Regulator

Quick

Connect

D24563

14- ENG

Image 14
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Important Safety Instructions Specification ChartSafety Guidelines Definitions What can Happen HOW to Prevent ITRisk of Explosion or Fire Risk of Bursting Risk from Flying ObjectsRisk to Breathing What can Happen HOW to Prevent ITRisk of Electrical Shock Risk of Falling Risk of BurnsRisk from Moving Parts Risk of Unsafe Operation Glossary AccessoriesAccessories Assembly Duty Cycle Risk of Electrical Installation Location of the Air Compressor Improper Grounding can Result in Electrical ShockExtension Cords Voltage and Circuit ProtectionOutlet Pressure Gauge The outlet OperationDescription of Operation Tank Pressure Gauge The tankHow to Use Your Unit Break-in ProcedureBefore Each Start-Up DrainCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankMotor Air Filter Inspection and ReplacementAir Compressor Pump Intake and Exhaust Valves Air FilterRing Service and AdjustmentsTo Replace or Clean Check Valve Nut Outlet Tube Pressure Relief Check ValveRegulator Arrow To Replace RegulatorRegulator Tank Outlet Pressure PressureGauge Quick Connect Storage Troubleshooting Problem Cause CorrectionPressure reading Check wiring connection Garantie Complète DE UN AN SUR LES Compresseurs D’AIR Pour Placer UNE CommandeTable DES Matières Sears Canada, Inc., Toronto, Ont. M5B 2B8Consignes DE Sécurité Importantes Tableau DES SpécificationsMesures DE Sécurité Définitions Prévention Risque D’EXPLOSION OU D’INCENDIERisque Risque D’ÉCLATEMENT Risque DE Projection D’OBJETSRisque DE Choc Électrique Risque PAR InhalationRisque DE Chute Risque DE BrûluresRisque Relié AUX Pièces Mobiles Risque PréventionRisque Dune Utilisation Dangereuse Lexique AccessoiresAccessoires Cycle DE Service AssemblageRisque DE Chocs Emplacement du compresseur dairDirectives DE Mise À LA Terre Rallonges Protection contre la surtension et protection du circuitDescription du fonctionnement UtilisationFamiliarisez-vous avec votre compresseur dair Arrêt de lappareil Utilisation de lappareilAvant le démarrage Procédures de rodageAvant chaque mise en marche Mise en marcheVérification de la soupape de sûreté EntretienResponsabilités du client Vidange du réservoirFiltre à air Filtre à air Inspection et remplacementMoteur Remplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesRemplacement du régulateur Régulateur FlècheRangement Serrer DépannageProblème Cause Correction Peut éclater ou exploserConsidérée normale Pas Surcharges déclenché 54- FR 55- FR D24563 Get it fixed, at your home or ours