STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary.

2.Set the On/Auto/Off lever to "OFF".

3.Turn the regulator counterclockwise and set the outlet pressure to zero.

4.Remove the air tool or accessory.

5.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately

20 psi. Release safety valve ring.

6.Drain water from air tank by opening drain valve on bottom of tank.

Water will condense in the air

tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

7.After the water has been drained, close the drain or drain valve.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

8.Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle.

Store the air compressor in a clean and dry location.

D24563

20- ENG

Image 20
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Important Safety Instructions Specification ChartSafety Guidelines Definitions What can Happen HOW to Prevent ITRisk of Explosion or Fire Risk of Bursting Risk from Flying ObjectsRisk to Breathing What can Happen HOW to Prevent ITRisk of Electrical Shock Risk of Falling Risk of BurnsRisk from Moving Parts Risk of Unsafe Operation Glossary AccessoriesAccessories Assembly Duty CycleInstallation Location of the Air CompressorRisk of Electrical Improper Grounding can Result in Electrical ShockExtension Cords Voltage and Circuit ProtectionOperation Description of OperationOutlet Pressure Gauge The outlet Tank Pressure Gauge The tankHow to Use Your Unit Break-in ProcedureBefore Each Start-Up DrainMaintenance To Check Safety ValveCustomer Responsibilities To Drain TankAir Filter Inspection and Replacement Air Compressor Pump Intake and Exhaust ValvesMotor Air FilterService and Adjustments To Replace or Clean Check ValveRing Nut Outlet Tube Pressure Relief Check ValveRegulator Arrow To Replace RegulatorRegulator Tank Outlet Pressure PressureGauge Quick Connect Storage Troubleshooting Problem Cause CorrectionPressure reading Check wiring connection Pour Placer UNE Commande Table DES MatièresGarantie Complète DE UN AN SUR LES Compresseurs D’AIR Sears Canada, Inc., Toronto, Ont. M5B 2B8Consignes DE Sécurité Importantes Tableau DES SpécificationsMesures DE Sécurité Définitions Prévention Risque D’EXPLOSION OU D’INCENDIERisque Risque D’ÉCLATEMENT Risque DE Projection D’OBJETSRisque DE Choc Électrique Risque PAR InhalationRisque DE Brûlures Risque Relié AUX Pièces MobilesRisque DE Chute Risque PréventionRisque Dune Utilisation Dangereuse Lexique AccessoiresAccessoires Cycle DE Service AssemblageRisque DE Chocs Emplacement du compresseur dairDirectives DE Mise À LA Terre Rallonges Protection contre la surtension et protection du circuitDescription du fonctionnement UtilisationFamiliarisez-vous avec votre compresseur dair Utilisation de lappareil Avant le démarrageArrêt de lappareil Procédures de rodageAvant chaque mise en marche Mise en marcheEntretien Responsabilités du clientVérification de la soupape de sûreté Vidange du réservoirFiltre à air Filtre à air Inspection et remplacementMoteur Remplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesRemplacement du régulateur Régulateur FlècheRangement Dépannage Problème Cause CorrectionSerrer Peut éclater ou exploserConsidérée normale Pas Surcharges déclenché 54- FR 55- FR D24563 Get it fixed, at your home or ours