Craftsman 919.7247 owner manual Service and Adjustments, To Replace or Clean Check Valve, Ring

Page 18

SERVICE AND ADJUSTMENTS

Unit cycles automatically when

power is on. When doing Maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.

Before servicing:

Unplug or disconnect electrica supply to the air compressor.

Bleed tank of pressure.

Allow the air compressor to cool.

To Replace or Clean Check Valve

1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.

2.Unplug outfit.

3.Remove the regulator ring and remove the console cover.

Regulator

Cover

Ring

 

4.Remove shrouds.

5.Using an adjustable wrench loosen outlet tube nut at air tank and pump. Carefully move outlet tube up away from check valve.

 

 

 

Nut

 

Outlet Tube

 

 

 

 

 

Pressure

 

 

 

 

Relief

 

 

 

 

 

Check

Tube

 

Valve

Nut

 

 

 

 

 

 

 

 

6.Using an adjustable wrench loosen pressure relief tube nut at air tank and pressure switch. Carefully move pressure relief tube away from check valve.

7.Unscrew the check valve (turn counterclockwise) using a 7/8" open end wrench. Note the orientation for reassembly.

8.Using a screwdriver, carefully push the valve disc up and down. NOTE: The valve disc should move freely up and down on a spring which holds the valve disc in the closed position, if not the check valve needs to be cleaned or replaced.

Screwdriver

In open position nothing is visible.

In closed position disc is visible.

9.Clean or replace the check valve. A solvent, such as paint or varnish remover can be used to clean the check valve.

10.Apply sealant to the check valve threads. Reinstall the check valve (turn clockwise).

11.Replace the pressure release tube. Tighten nuts.

D24563

18- ENG

Image 18
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Specification Chart Safety Guidelines DefinitionsImportant Safety Instructions HOW to Prevent IT Risk of Explosion or FireWhat can Happen Risk of Bursting Risk from Flying ObjectsWhat can Happen HOW to Prevent IT Risk of Electrical ShockRisk to Breathing Risk of Burns Risk from Moving PartsRisk of Falling Risk of Unsafe Operation Accessories AccessoriesGlossary Assembly Duty CycleRisk of Electrical InstallationLocation of the Air Compressor Improper Grounding can Result in Electrical ShockExtension Cords Voltage and Circuit ProtectionOutlet Pressure Gauge The outlet OperationDescription of Operation Tank Pressure Gauge The tankHow to Use Your Unit Break-in ProcedureBefore Each Start-Up DrainCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankMotor Air Filter Inspection and ReplacementAir Compressor Pump Intake and Exhaust Valves Air FilterRing Service and AdjustmentsTo Replace or Clean Check Valve Nut Outlet Tube Pressure Relief Check ValveTo Replace Regulator Regulator Tank Outlet Pressure PressureGauge Quick ConnectRegulator Arrow Storage Troubleshooting Problem Cause CorrectionPressure reading Check wiring connection Garantie Complète DE UN AN SUR LES Compresseurs D’AIR Pour Placer UNE CommandeTable DES Matières Sears Canada, Inc., Toronto, Ont. M5B 2B8Tableau DES Spécifications Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Risque D’EXPLOSION OU D’INCENDIE RisquePrévention Risque D’ÉCLATEMENT Risque DE Projection D’OBJETSRisque DE Choc Électrique Risque PAR InhalationRisque DE Chute Risque DE BrûluresRisque Relié AUX Pièces Mobiles Risque PréventionRisque Dune Utilisation Dangereuse Accessoires AccessoiresLexique Cycle DE Service AssemblageEmplacement du compresseur dair Directives DE Mise À LA TerreRisque DE Chocs Rallonges Protection contre la surtension et protection du circuitUtilisation Familiarisez-vous avec votre compresseur dairDescription du fonctionnement Arrêt de lappareil Utilisation de lappareilAvant le démarrage Procédures de rodageAvant chaque mise en marche Mise en marcheVérification de la soupape de sûreté EntretienResponsabilités du client Vidange du réservoirFiltre à air Inspection et remplacement MoteurFiltre à air Remplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesRemplacement du régulateur Régulateur FlècheRangement Serrer DépannageProblème Cause Correction Peut éclater ou exploserConsidérée normale Pas Surcharges déclenché 54- FR 55- FR D24563 Get it fixed, at your home or ours