Craftsman 919.7247 owner manual Risque DE Choc Électrique, Risque PAR Inhalation

Page 28

DANGER

RISQUE DE CHOC ÉLECTRIQUE

RISQUE

VOTRE COMPRESSEUR D’AIR EST ALIMENTÉ PAR ÉLECTRICITÉ. COMME AVEC TOUS LES APPAREILS ÉLECTRIQUES,

SI L’APPAREIL N’EST PAS UTILISÉ DE FAÇON APPROPRIÉE, IL PEUT CAUSER DES CHOCS ÉLECTRIQUES.

TOUTE RÉPARATION EFFECTUÉE PAR UNE PERSONNE NON QUALIFIÉE PEUT ENTRAÎNER DES BLESSURES GRAVES OU LA MORT PAR ÉLECTROCUTION.

MISE À LA TERRE : LE DÉFAUT D’ÉTABLIR

UNE MISE À LA TERRE APPROPRIÉE POUR CET APPAREIL PEUT ENTRAÎNER DES BLESSURES GRAVES OU LA MORT PAR ÉLECTROCUTION. VOIR LES DIRECTIVES DE MISE À LA TERRE.

PRÉVENTION

NE JAMAIS FAIRE FONCTIONNER LE COMPRESSEUR À L’EXTÉRIEUR LORSQU’IL PLEUT OU DANS DES CONDITIONS HUMIDES.

NE JAMAIS FAIRE FONCTIONNER LE COMPRESSEUR SANS LES COUVERCLES DE PROTECTION OU LORSQUE CEUX-CI SONT ENDOMMAGÉS.

TOUT CÂBLAGE ÉLECTRIQUE OU TOUTE RÉPARATION REQUIS SUR CET APPAREIL

DEVRAIT ÊTRE EFFECTUÉ PAR LE PERSONNEL D’UN CENTRE DE SERVICE APRÈS-VENTE AUTORISÉ, CONFORMÉMENT AUX CODES ÉLECTRIQUES NATIONAUX ET LOCAUX.

S’ASSURER QUE LE CIRCUIT ÉLECTRIQUE ALIMENTANT LE COMPRESSEUR FOURNIT

UNE MISE À LA TERRE ÉLECTRIQUE APPROPRIÉE, UNE TENSION APPROPRIÉE ET UNE PROTECTION ADÉQUATE PAR FUSIBLES.A

DANGER

RISQUE PAR INHALATION

RISQUE

L'AIR COMPRIMÉ DE VOTRE COMPRESSEUR D'AIR N'EST PAS SÉCURITAIRE POUR L'INHALATION. LE JET D'AIR PEUT CONTENIR DU MONOXYDE DE CARBONE, DES VAPEURS TOXIQUES OU DES PARTICULES SOLIDES DU RÉSERVOIR.

L'INHALATION DE CES CONTAMINANTS PEUT CAUSER DES BLESSURES GRAVES OU LA MORT.

LES MATIÈRES VAPORISÉES TELLES QUE LA PEINTURE, LES SOLVANTS DE PEINTURE, LES DÉCAPANTS, LES INSECTICIDES ET LES HERBICIDES CONTIENNENT DES VAPEURS

NOCIVES ET TOXIQUES.

PRÉVENTION

L'AIR OBTENU DIRECTEMENT DU COMPRESSEUR NE DEVRAIT JAMAIS ÊTRE

UTILISÉ COMME SOURCE D'AIR POUR LES ÊTRE HUMAINES. SI L'AIR PRODUIT PAR CE COMPRESSEUR SERA UTILISÉ POUR LA RESPIRATION, IL FAUT INSTALLER DES

FILTRES APPROPRIÉS AINSI QUE DU MATÉRIEL DE SÉCURITÉ. LES FILTRES EN

LIGNE ET LE MATÉRIEL DE SÉCURITÉ UTILISÉS AVEC LE COMPRESSEUR DOIVENT ÊTRE DANS LA MESURE DE TRAITER L'AIR DE FAÇON À CE QU'IL RÉPONDE À TOUTES LES NORMES NATIONALES ET LOCALES APPLICABLES AVANT D'ÊTRE UTILISÉ POUR LES ÊTRES HUMAINES.

TRAVAILLER DANS UN ENDROIT OÙ IL Y A UNE BONNE VENTILATION TRANSVERSALE. BIEN LIRE ET RESPECTER LES DIRECTIVES DE SÉCURITÉ INDIQUÉES SUR L’ÉTIQUETTE OU LA FICHE SIGNALÉTIQUE DE LA MATIÈRE QUI EST VAPORISÉE. PORTER UN

RESPIRATEUR HOMOLOGUÉ PAR LE NIOSH/MSHA ET CONÇU POUR L’APPLICATION EN QUESTION.

D24563

32- FR

Image 28
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Risk of Explosion or Fire HOW to Prevent ITWhat can Happen Risk of Bursting Risk from Flying ObjectsRisk of Electrical Shock What can Happen HOW to Prevent ITRisk to Breathing Risk from Moving Parts Risk of BurnsRisk of Falling Risk of Unsafe Operation Accessories AccessoriesGlossary Assembly Duty CycleInstallation Location of the Air CompressorRisk of Electrical Improper Grounding can Result in Electrical ShockExtension Cords Voltage and Circuit ProtectionOperation Description of OperationOutlet Pressure Gauge The outlet Tank Pressure Gauge The tankHow to Use Your Unit Break-in ProcedureBefore Each Start-Up DrainMaintenance To Check Safety ValveCustomer Responsibilities To Drain TankAir Filter Inspection and Replacement Air Compressor Pump Intake and Exhaust ValvesMotor Air FilterService and Adjustments To Replace or Clean Check ValveRing Nut Outlet Tube Pressure Relief Check ValveRegulator Tank Outlet Pressure PressureGauge Quick Connect To Replace RegulatorRegulator Arrow Storage Troubleshooting Problem Cause CorrectionPressure reading Check wiring connection Pour Placer UNE Commande Table DES MatièresGarantie Complète DE UN AN SUR LES Compresseurs D’AIR Sears Canada, Inc., Toronto, Ont. M5B 2B8Mesures DE Sécurité Définitions Tableau DES SpécificationsConsignes DE Sécurité Importantes Risque Risque D’EXPLOSION OU D’INCENDIEPrévention Risque D’ÉCLATEMENT Risque DE Projection D’OBJETSRisque DE Choc Électrique Risque PAR InhalationRisque DE Brûlures Risque Relié AUX Pièces MobilesRisque DE Chute Risque PréventionRisque Dune Utilisation Dangereuse Accessoires AccessoiresLexique Cycle DE Service AssemblageDirectives DE Mise À LA Terre Emplacement du compresseur dairRisque DE Chocs Rallonges Protection contre la surtension et protection du circuitFamiliarisez-vous avec votre compresseur dair UtilisationDescription du fonctionnement Utilisation de lappareil Avant le démarrageArrêt de lappareil Procédures de rodageAvant chaque mise en marche Mise en marcheEntretien Responsabilités du clientVérification de la soupape de sûreté Vidange du réservoirMoteur Filtre à air Inspection et remplacementFiltre à air Remplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesRemplacement du régulateur Régulateur FlècheRangement Dépannage Problème Cause CorrectionSerrer Peut éclater ou exploserConsidérée normale Pas Surcharges déclenché 54- FR 55- FR D24563 Get it fixed, at your home or ours