MAINTENANCE

Customer Responsibilities

Check Safety Valve

Drain Tank

Air Filter

Air compressor pump intake and exhaust valves

Before each use

Daily or after each use

Every

100Yearly

hours

1

1- more frequent in dusty or humid conditions

Unit cycles automatically when

power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed "Off" all air pressure.

NOTE: See Operation section for the location of controls.

To Check Safety Valve

Risk of Bursting. If the safety valve

does not work properly, over- pressurization may occur, causing air tank rupture or an explosion.

Risk from Flying Objects. Always

wear certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields

1.Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve

is stuck or does not operate smoothly, it must be replaced with the same type of valve.

To Drain Tank

Risk of Unsafe Operation. Risk from noise. Air tanks contain high

pressure air. Keep face and other body parts away from outlet of

drain. Use ANSI Z87.1 eye protection (CAN/CSA Z94.3) when draining as debris can be kicked up into face. Use ear protection (ANSI S12.6 (S3.19) hearing protection) as air flow noise is loud when draining.

1.Set the On/Auto/Off lever to "Off".

2.Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero.

3.Remove the air tool or accessory.

4.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

5.Drain water from air tank by opening drain valve on bottom of tank.

Risk of Bursting. Water will condense

in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

Risk of Property Damage. Drain

water from air tank may contain oil and rust which can cause stains.

6.After the water has been drained, close the drain valve. The air compressor can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled.

15 - ENG

A17883

Image 15
Contents AIR Compressor Warranty Table of ContentsModel No 919.167321 Specification ChartSafety Guidelines Definitions Important Safety InstructionsRisk to Breathing Asphyxiation Risk of Explosion or Fire What can Happen HOW to Prevent ITWhat can Happen HOW to Prevent IT HazardRisk of Bursting Attachments & accessoriesRisk of Electrical Shock What can Happen HOW to Prevent IT Electrical Grounding Failure toRisk from Flying Objects Risk from Moving Parts Risk of HOT Surfaces What can Happen HOW to Prevent ITRisk of Unsafe Operation What can Happen HOW to Prevent IT Risk of FallingRisk from Noise Duty Cycle AccessoriesAccessories GlossaryGrounding can Result Electrical Shock AssemblyInstallation Location of the Air CompressorVoltage and Circuit Protection Extension Cords Operation Know Your Air Compressor Description of Operation Pressure Release Valve How to StopBefore Starting Before Each Start-UpHow to Start To Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesAir Filter Inspection and Replacement Air Compressor Pump Intake and Exhaust ValvesAir Filter Nut Outlet Tube Pressure Relief Check Valve Service and AdjustmentsTo Replace or Clean Check Valve To Replace RegulatorRegulator Arrow StorageOutlet Pressure Gauge Regulator Quick Connect NipleProblem Cause Correction TroubleshootingBeing used Check wiring connection Garantía ContenidoModelo Nº 919.167321 Cuadro DE EspecificacionesDefiniciones DE Normas DE Seguridad Instrucciones Importantes DE SeguridadPeligro Riesgo Respiratorio Asfixia¿QUÉ Puede SUCEDER? Cómo Evitarlo Elementos y accesorios Riesgo DE ExplosiónRiesgo DE Superficies Calientes Riesgo DE Objetos DespedidosRiesgo DE Operación Insegura Riesgo POR Piezas Móviles ¿QUÉ Puede SUCEDER? Cómo EvitarloRiesgo POR Ruidos Riesgo DE CaídasAccesorios GlosarioAccesorios Ciclo DE ServicioUbicación del compresor de aire EnsamblajeInstalación DesempaqueCables de extensión eléctrica Protección del voltaje y del circuitoRiesgo de Operación Descripción de operaciones On/Auto Off Switch Safet y Valve RegulatorOperación Conozca su compresor de aireAntes de cada puesta en marcha Antes de poner en marchaCómo detenerla Procedimiento para el asentamientoCómo verificar la válvula de seguridad MantenimientoCómo poner en marcha Responsabilidades del clienteFiltro de aire Cómo drenar el tanqueFiltro de Aire Inspección y reemplazo Superficies calientes. RiesgoDe presión Dora Tuerca Servicio Y AjustesPara reemplazar o limpiar la válvula retención Tuerca Salida Tubo aliviadorRegulador Flecha Para reemplazar el reguladorRegulador Conector rápido ReguladorRiesgo de Explosión. El agua AlmacenajeProblème Cause Correction DépannageSoire est utilisé Le relevé dePression sur le Manomètre duTourne pas Le moteur neA17883 Contratos de Protección Maestra Master Protection AgreementsMY-HOME Sears Parts and Repair CenterCanada